Riello RL 190/M Instrucciones De Instalación, Funcionamiento Y Mantenimiento página 31

Quemadores de gasóleo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SYMBOL (1)
FAULT
Smoke in flame - dark Bacharach
Dirty combustion head
During operation, the burner stops
I
in lock out
When the burner does not fire or comes to a halt following a fault, the symbol which appears on control box 24) (Fig. 1, page 7)
(1)
indicates the type of problem.
The fuse is located in the rear part of the control box 24) (Fig. 1, page 7). A pull-out fuse is also available as a spare part which
(2)
can be fitted after breaking the tang on the panel which holds it in place.
56 - Not enough air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
57 - Nozzle worn or dirty . . . . . . . . . . . . . . . . . . . . . . . . . . . .
58 - Nozzle filter clogged . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59 - Erroneous pump pressure . . . . . . . . . . . . . . . . . . . . . . .
60 - Flame stability disk dirty, loose, or deformed . . . . . . . . .
61 - Boiler room air vents insufficient . . . . . . . . . . . . . . . . . .
- yellow Bacharach 62 - Too much air. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63 - Nozzle or filter dirty. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64 - Unsuitable nozzle delivery or angle . . . . . . . . . . . . . . . .
65 - Loose nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
66 - Impurities on flame stability disk. . . . . . . . . . . . . . . . . . .
67 - Erroneous head adjustment or not enough air . . . . . . . .
68 - Blast tube length unsuited to boiler . . . . . . . . . . . . . . . .
69 - Dirty or defective photocell . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
PROBABLE CAUSE
29
GB
SUGGESTED REMEDY
Adjust head and fan gate
Replace
Clean or replace
Adjust
Clean, tighten in place, or replace
Increase
Adjust head and fan gate
Replace
See recommended nozzles
Tighten
Clean
Adjust, open air damper
Contact boiler manufacturer
Clean or replace
20024198