Troubleshooting
Danger
Danger of injury by electric shock.
–
First pull out the plug from the mains be-
fore carrying out any tasks on the ma-
chine.
Get the electrical components checked
–
and repaired only by authorised cus-
tomer service persons.
Contact an authorised customer service
–
person in case of problems not men-
tioned in this chapter or if you are in
doubt or when you have been explicitly
asked to do so.
No water exiting from nozzle
Fill up fresh water reservoir.
Check couplings on the fresh water
hose for proper connection.
Detach nozzle attachment and remove,
clean or replace nozzle.
Clean the sieve in the fresh water reser-
voir.
Detergent pump defective, contact Cus-
tomer Service.
Spray stream one-sided
Clean nozzle mouthpiece.
Insufficient vacuum performance
Check the correct positioning of the lid.
Clean seal on lid and surface on the ap-
pliance.
Clean the fluff filter.
Check suction hose for blockages;
clean if required.
Detergent pump noisy
Fill up fresh water reservoir.
Accessories and Spare Parts
Only use accessories and spare parts
–
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
At the end of the operating instructions
–
you will find a selected list of spare parts
that are often required.
For additional information about spare
–
parts, please go to the Service section
at www.kaercher.com.
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.