Safety notes
Prevent danger resulting from damaged power
supply cables. In the case of damage, the power
supply cable must be replaced by the manufacturer
or his customer service department or an equally
qualified person.
• Installation is only possible in frost-free rooms.
• The optional power supply unit is only suitable for
indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• The maximum permissible distance between the digital
controller and the functional unit is 16.4 feet.
Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
Specifications
• Flow pressure:
- min.
- recommended
• Operating pressure max.
• Test pressure
If static pressure exceeds 0.5 MPa (72.5 psi), a pressure-
reducing valve must be fitted.
Avoid major pressure differences between hot and cold water
supply.
• Max. flow
8.2 L/min or 2.2 gpm / 0.41 MPa (60 psi)
• Hot water supply temperature:
Recommended (energy saving):
• Voltage supply:
• Power consumption:
• Radio frequency:
• Transmitter power:
• Emergency power supply: 6 V lithium battery (type CR-P2)
• Control panel battery:
3x 3 V lithium batteries (type CR 2450)
• Automatic safety shut-off (plant setting):
• Safety stop (plant setting):
• Type of protection:
• Water connection
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
1
English
0.1 MPa (14.5 psi)
0.2 - 0.5 MPa (29 - 72.5 psi)
max. 1.0 MPa (145 psi)
1.6 MPa (232 psi)
min. 122 °F - max. 176 °F
140 °F
120 V AC, 50/60 Hz
9 VA
2.4332 GHz
< 1 mW
60 s
108 °F
- Faucet
IP 66
- Battery box
IP 59K
- Digital controller
IP X5
cold - right/hot - left
B
2
2,500 V
212 °F
Approval and conformity
This device complies with part 15 of the FCC Rules (USA) and
with the RSS of the IC Rules (Canada).
Operation is subject to the following two conditions:
This device may not cause harmful interference, and this
device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance may void the user's authority to
operate the equipment.
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This
work must be carried out in accordance with
the regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well as
all national and local regulations.
Installation
Install spout, see fold-out page II, Figs. [1] and [2].
Install pop-up waste (65 818), see fold-out page I.
Seal plug-hole rim.
Insert batteries into digital controller, see technical product
information for the digital controller.
Insert batteries with correct polarity.
The digital controller is logged to the function unit by plant
setting.
Fasten digital controller, see technical product information
for the digital controller.
The adhesive film must harden 24 hours befor pull off the
digital controller the first time.
Install functional unit, see Fig. [3].
Flush piping system prior and after installation of faucet
thoroughly!
Connect functional unit, see Figs. [4] and [5].
Open hot and cold water supply and check connections
for leakage. Water flows until functional unit and power supply
are connected.
Connect battery housing to functional unit, see Fig. [4].
Establish voltage supply via plug-in power supply, see Fig.
[4] and fold-out page I.
The connecting wire can be extended using the extension
cable special accessory (Prod. no. 47 727). A maximum of two
extension cables can be joined together (max. 19.7 ft).
The reception can be improved and thermal disinfection
carried out using the transceiver special accessory
(Prod. no. 36 356).
Approx. 10 seconds after the voltage supply is established
there are two brief water pulses and the buttons of the digital
controller are now inoperative for 60 seconds.
The faucet must be adapted to the local conditions, see
section Selection menu of the digital controller, F2 -
Calibration.
Settings during power failure/when changing batteries
No settings saved by the user will be lost when changing the
batteries or in the event of an interruption of the power supply
to the functional unit.