7.

BLOWER REMOVAL (

These range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge
configuration, disassemble the blower from the inner top of the hood (see procedure below). It will be assembled to the inner back of the
hood once the hood is mounted on the wall.
1) Unplug the blower.
HE0123

8. INSTALL THE ADAPTER/DAMPER

H
ORIZONTAL DISCHARGE
Mount the 3¼" x 10" adapter/damper to the back of the hood using
2 no. 8 x 3/8" screws (included). Seal the adapter/damper to the hood using
metal foil duct tape.
NOTE: The wall ducting must be properly prepared to receive the adapter.
Before performing the installation, make sure the adapter fits easily
in the duct.
V
ERTICAL DISCHARGE
Mount the 3¼" x 10" adapter/damper to the top of the hood using 2 no. 8 x 3/8" screws
(included). Seal the adapter/damper to the hood using metal foil duct tape.
HORIZONTAL DISCHARGE ONLY
2) Using a 5/16" socket, or a Robertson or a Phillips no. 2 screwdriver,
remove the 4 blower mounting screws (2 on each side) from the inner
top of the hood. Set the blower and screws aside.
HD0385
)
L
EFT SIDE MOUNTING
SCREW LOCATIONS
HJ0062
HJ0065
7
R
IGHT SIDE MOUNTING
SCREW LOCATIONS
HD0386
S
CREW LOCATIONS
S
CREW LOCATIONS

Publicidad