MACHINE AND MANUFACTURER IDENTIFICATION

PART NUMBER
C

MACHINE DESCRIPTION

PUMP: Five-chamber positive-displacement diaphragm pump.
MOTOR: Asynchronous motor, single-phase, 2 pole, closed type, protection class IP55 according to CEI-EN 60034-5.
C.1

HANDLING AND TRANSPORT

Due to the limited weight and dimensions of the pumps, special lifting equipment is not required to handle them. The
pumps are carefully packed before dispatch. Check the packing when receiving the material and store in a dry place.

GENERAL WARNINGS

D
Important pre-
To ensure operator safety and to protect the pump from
potential damage, workers must be fully acquainted with
cautions
this instruction manual before performing any operation.
Symbols used
The following symbols will be used throughout the manual
to highlight safety information and precautions of particular
in the manual
importance:
WARNING
This symbol indicates safe working practices for
operators and/or potentially exposed persons.
NOTICE
This symbol indicates that there is risk of damage to
the equipment and/or its components.
NOTE
This symbol indicates useful information
Manual preser-
This manual should be complete and legible throughout.
It should remain available to end users and specialist
vation
installation and maintenance technicians for consultation at
any time.
Reproduction
All reproduction rights are reserved by Graco Inc. The text
cannot be reprinted without the written permission
rights
E

FIRST AID RULES

Contact with
In the event of problems developing following EYE/
SKIN CONTACT, INHALATION or INGESTION of the treated
the flui
product, please refer to the SAFETY DATA SHEET/ASU32 /
DEF / AD-Blue (ISO22241)
Persons who
Disconnect the power source, or use a dry insulator to
protect yourself while you move the injured person away
have suffe ed
from any electrical conductor. Avoid touching the injured
electric shock
person with your bare hands until he is far away from any
conductor. Immediately call for help from qualified and
trained personnel. Do not operate switches with wet hands.
NOTE
Please refer to the safety data sheet for the fluid
M0309
Graco Inc.
P.O. Box 1441
Mpls, MN 55440
MADE IN ITALY
127643
MAX WPR 345 kPa (3.4 bar)(50 psi)
12V D
C
22A
2600 Rpm
TECHNICAL
DUTY CYCLE 20´ON/20´OFF
DATA
36 lpm/9.5 gpm
-5C to 40C 23F to 104F
IP55/RAINPROOF
LOT XXXXXXX
Read instruction manual 333466.
Artwork No. 294247 Rev. B
DATE CODE
F 14 A
XXXX
260 W
www.graco.com
EN