DESCRIPTION
FUNCTION
L
Connector L 230V supply
N
Connector N 230V supply
Battery
Connector for a battery kit +/-
475E + 041ADBL-0115
Motor MASTER
motor 1 (master opens first)
Motor SECOND
motor 2 (Second opens second)
24V/150mA
Flashing light (accessory)
MASTER
Motor1
BRN
brown cable
GRN
green cable
WHT
white cable
YEL
yellow cable
SECOND
Motor2
BRN
brown cable
GRN
green cable
WHT
white cable
YEL
yellow cable
"Key symbol"
key switch
COM
negative pole
PHOTO1
Photocells 1
PHOTO2
Photocells 2
COM
negative pole
STOP 8.2KOhms
connector for emergency switch or
safety edge with 8.2KOhms
RADIO
connection for 801719 radio receiver
E-lock symbol
connection for E-lock control board
INPUT 24VAC
24V power input from transformer.
Can be connected with any polarity.
Transformer 230VAC
230V supply to transformer. Can be
connected with any polarity.
250V/2A
Fuse 250V/2A (2x included)
DESCRIPTION OF PUSH BUTTONS
P1 button to program "simple" mode
P2 button to program "individual" mode
P3 button to program "Timer to close"
Description of LED's (light-emitting diode)
Description
Colour
STOP/8.2KOhms
green
"Key symbol"
red
PHO2
red
PHO1
red
LEARN
yellow
DIAGNOSTIC
red
Only modify settings when control bord
is disconnected. Otherwise modifications will
not be accepted!!!
Function
monitors emergency switch
or safety edge
ON: blocks control board
OFF: OK
key switch
ON: key switch is operating
OFF: key switch is not
operating
Photocells 2
ON: OK (active)
OFF: no photocell fitted
Photocells 1
ON: OK (active)
OFF: no photocell fitted
learn mode indication
ON: learn mode active
OFF: learn mode inactive
diagnosis mode
Refer to FAQ's