Indication Of The Diagnosis Led - LiftMaster ART200K Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71

INDICATION OF THE DIAGNOSIS LED

Indication
Description
1x blinking
Motor 1 has insufficient connection to control board
2x blinking
Motor 2 has insufficient connection to control board
3x blinking
Limits for motor 2 have not been accepted
A: After or during first travel: operator did not open
open wide enough to meet not meet passpoint
(cam did not operate switch)
B: Motorcables have insufficient connection to contol board
Yellow or white cable not wired or badly connected
4x blinking
Limits for motor 1 have not been accepted
5x blinking
Travel has not been programmed
The process of programming has been interrupted
6x blinking
Force to operate the gate is too high
A: Gate is out of order
B: Gate is rough-running
C: Gate stopped through windload
7x blinking
Photocells 1 block installation
A: Object blocks photocells
B: Alignment of the lenses is incorrect
C: Power supply to photocells is insufficient
8x blinking
Photocells 2 block installation
9x blinking
Emergency stop switch blocks installation
10xblinking
Safety edge blocks installation
A: Object obstructs safety edge
B: Defective safety edge
C: Power too low or broken wire in supply
11xblinking
Power supply to control board is too low
A: Defective supply 230V or malfunctioning contact
B: Broken wire in supply cable (copper cable)
C: The battery (accessory) to operate the gate whilst
power failure is dead.
12xblinking
EEPROM Fault
Power up failed
Remedy
Green or white cable not wired or badly connected Check
terminals precisely. Consider wire lengths
Refer to 1x blinking
A: Open gate wide enough when programming the travel. Make
sure cam passes all 3 states (switch free, pushed, free)
B: Check terminals precisely. Consider wire lengths
Refer to 3x blinking
Repeat programming travel
A: Repair gate
B: Check if gate can be easily moved
C: Do not operate gate by windstorm
D: Reprogram travel to achieve sufficient level of fo
A: Remove object
B: Check alignment
C: Check cable widths and contacts
Refer to 7x blinking
A: Check wiring
B: Check basic setting of control board (Jumpers)
A: Remove object
B: Check wiring. Check resistor 8.2KOhms
C: Check basic setting of control board (Jumpers)
A: Check electric contact
B: Check by electrician
C: Allow battery to charge 24 hours
Replace contol board

Publicidad

Tabla de contenido
loading

Tabla de contenido