Performance Data - Pentair F3000-B2B Manual De Instrucciones

Ocultar thumbs Ver también para F3000-B2B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32

PERFORMANCE DATA

Important notice: read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test conditions
Flow rate
F3000-B2B
= 2,27 Lpm
F3000-B2M
= 2,27 Lpm
Filter capacity
F3000-B2B
= 2'555 L
F3000-B2M
= 2'555 L
Inlet pressure
= 4,1 bar
Temperature
= 20°C+/- 2,5°C
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating requirements for F3000-B2B and F3000-B2M systems:
Pressure
= 2,75-6,89 bar
Temperature
= 4,4–37,8°C
CARTRIDGE SEQUENCE
F3000-B2B
F3000-B2M
F3000-B2B, F3000-B2M Filtration systems instruction manual • 9
F3000-B2B, F3000-B2M SYSTEMS
INSTALLED WITH F2B2-RC2 FILTER
CARTRIDGE SET AND F1S5-RC
CARTRIDGE
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Conforms to NSF/ANSI 53 for VOC reduction. See performance data
sheet for individual contaminant and reduction performance.
Model F3000-B2B, F3000-B2M Systems
Max. permissible
Influent challenge
Substance
product water
concentration
concentration
Standard 42
Chlorine
2,0 mg/L±10%
taste & odor
Particulates
At least 10'000
(0,5-<1uM)
particulates/mL
class 1*
Standard 53
Cysts **
Minimum 50'000/L
Atrazine
0,009 mg/L ± 10%
0,003 mg/L
Lead (pH
0,15 mg/L ± 10%
0,010 mg/L
6,5)
Lead (pH
0,15 mg/L ± 10%
0,010 mg/L
8,5)
Lindane
0,002 mg/L ± 10%
0,0002 mg/L
Chloroform
(VOC
0,300mg/L ± 10%
surrogate
chemical)
Flow rate = 2,2 Lpm; capacity = 2'555 L or 12 months
Testing was performed under standard laboratory conditions, actual
performance may vary.
* Reduces particles as small as 0,5-1 micron in size by mechanical
means
** NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
The Model F3000-B2B and F3000-B2M are tested and certified by
NSF International aganist NSF/ANSI Standard 42 and 53 for the
reduction of substances specified on the performance data sheet.
EPA Est. 082989-CHN-001
Reduction
Minimum
Average
requirements
reduction
reduction
≥50%
95,9%
>85%
97,9%
99,95%
99,97%
99,99%
90,5%
93,7%
99,3%
99,9%
99,3%
99,6%
94,8%
97,4%
96,5%
98,8%

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

F3000-b2mF2000-b2bF2000-b2m

Tabla de contenido