PERFORMANCE DATA

IMPORTANT:
Read this performance data and compare the capabilities of this
system with your actual water treatment needs.
It is recommended that before installing a water treatment
system, you have your water supply tested to determine your
actual water treatment needs.
Testing was performed under standard laboratory conditions,
actual performance may vary.
TEST CONDITIONS
Flow Rate:
Filter Capacity:
Inlet Pressure:
Temperature:
OPERATING REQUIREMENTS
FOR THE LR-1500 SYSTEM:
Temperature Range:
Pressure Range:
The Model LR-1500 is Tested and Certified by NSF International against NSF/ANSI
Standard 42, 53, and CSA B483.1 for the reduction of the claims specified on the
Performance Data Sheet.
C
US
WARNING
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction
may be used on disinfected waters that may contain filterable
cysts.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, influent will be
treated to remove chlorine.
• 6 •
2.5 GPM (9.46 LPM)
1500 gallons (5678 liters)
60 psi (4.1 bar)
68°F ± 5°F (20°C ± 2.5°F)
40°F–100°F (4.4-37.8°C)
40–125 psi (2.75-8.62 bar)
LR-1500 SYSTEM INSTALLED WITH
LR-FB10 FILTER CARTRIDGE
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of substances listed below. The concentration of the
indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system as specified in NSF/ANSI 42 and 53.
Model LR-1500
Influent Challenge
Substance
Concentration
Standard 42
Chlorine
2.0 mg/L ± 10%
Taste and Order
Standard 53
Cysts**
Minimum 50,000/mL
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Flow rate = 2.5 gpm (9.46 L/min); Capacity = 1500 gallons (5678 L) or 12 months.
Testing was performed under standard laboratory conditions, actual performance
may vary.
* Reduces particles as small as 0.5-1 micron in size by mechanical means.
** NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and
Giardia by mechanical means.
EPA 090375-MEX-001
Max. Permissible
Product Water
Reduction
Minimum
Average
Concentration
Requirements
Reduction
Reduction
≥50%
97.4%
99.95%
>99.99%
0.010 mg/L
99.6%
0.010 mg/L
99.7%