Goulds Pumps GL Serie Instrucciones De Instalación, Funcionamiento Y Mantenimiento página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

adequately sized crane, carefully remove the mo-
tor. DO NOT rest the motor on the motor shaft.
5. Remove the 4 tie rod nuts and lock washers.
6. Carefully remove the motor adapter by sliding it
up the pump shaft. Larger units may require an
adequately sized crane to lift the motor adapter.
DO NOT damage the shaft.
NOTICE: EDGES OF THE STAINLESS STEEL PARTS
ARE SHARP . WEAR APPROPRIATE PRO-
TECTIVE CLOTHING.
7. To gain access to the mechanical seal, it is neces-
sary to remove the stainless steel upper plate
which is held in place by an O-ring located under
the plate rim. Place a small block of wood against
the underside of the rim and, while moving
around the rim, tap with a mallet against the block
until the upper plate loosens. Remove the upper
plate and O-ring from the pump casing. Discard
the O-ring.
8. Remove the stationary element from the upper
plate. With a clean cloth, wipe the upper plate
bore clean and inspect for damage. Replace the
upper plate, as required.
9. Remove the top (vented) stainless steel inner cas-
ing. Grasp the pump shaft, below the mechanical
seal, and move it sharply back and forth to free
the fi rst stage from the lower pump body. Remove
the entire stack assembly from the pump external
sleeve.
10. Slide the mechanical seal rotary element from the
pump shaft. Discard the entire mechanical seal
assembly. Clean shaft with lint free cloth or
alcohol swab.
11. Lubricate the shaft and inside of the new mechani-
cal seal assembly with water based lubricant.
12. To install a new mechanical seal rotary assembly,
slide the assembly onto the pump shaft, spring end
fi rst. Be sure the seal face is towards the motor.
DO NOT scratch or otherwise damage the seal
face. With a clean, lint free cloth or alcohol swab,
wipe the seal face clean of all lubricant or debris.
13. Lubricate the outside of the new mechanical seal
stationary element with a water based lubricant.
14. Insert the stationary seat into the seal housing with
the seal face out. DO NOT scratch or otherwise
damage the seal face. Insure that the stationary
seat is fully seated into the seal housing. With a
clean, lint free cloth or alcohol swab, wipe the seal
face clean of all lubricant or debris.
NOTE: Do not use grease or heavy oil as an
installation lubricant. Any oil or grease on
the seal faces may cause seal to leak.
15. With a new O-ring, install the seal housing onto
the pump shaft, seating the plate fully and square-
ly onto the pump outer shell.
16. Place the motor adapter over the 4 tie rod bolts,
using an adequately sized crane when required,
and install the 4 lock washers and tie rod nuts.
Torque the nuts, in sequence, to the value pro-
vided in the "ENGINEERING DATA" section of
this manual.
17. With an adequately sized crane, carefully lower
the motor onto the motor adapter, lining up the
electrical conduit connection and the 4 motor
adapter bolt holes, as required.
18. Install the 4 motor hex cap screws, torquing to the
value provided in the "ENGINEERING DATA"
section of this manual.
19. Place the coupling drive pin into the pump shaft
and install the coupling halves onto the motor and
pump shafts. Install the 4 coupling socket head
screws, lock washers and nuts, DO NOT tighten.
20. Position the motor assembly shim between the
coupling and the motor adapter. If the motor
assembly shim is not available, a 0.203" (5 mm)
shim may be used to locate the pump shaft assem-
bly and to set the correct height.
21. Tighten the 4 coupling socket head screws,
torquing screws to values provided in the "ENGI-
NEERING DATA" section of this manual. Tighten
evenly so that the gap between the halves is equal
side to side and top to bottom.
22. Install the 2 coupling guard halves.
A
MECHANICAL SEAL OPTIONS
Code
No.
A
B
Mechanical
Seal
C
D
L
Cartridge
Seal
P
Metal parts on all seals are 316SS. When reordering units with previous seal op-
tions 2, 3 or 5 review application and order new seal option from above chart.
1. Close all necessary suction and discharge valves to
isolate the pump from the system.
2. Drain the liquid from the pump by removing the
drain plug and opening the needle valve on the
vent plug.
3. Remove the coupling guards, the 4 coupling hex
cap screws, the coupling and coupling drive pin.
See steps 1-3.
4. Remove the 4 motor hex cap screws (inner
screws) on the seal housing. See step 4.
5. Remove the seal housing plate using the two
tapped holes provided. Threading 2 of the hex
cap screws into these holes and evenly tighten-
ing the screws. Lift and remove the seal housing
between the pump and motor shaft. Exercise care
when sliding the seal housing between the shaft to
prevent damage to the stationary seat. See step 5.
6. Turn the seal housing upside down and remove
the stationary seat and o-ring. Remove and dis-
card the large o-ring used to seal the seal housing
to the pump head. Inspect the seal seat for any
burrs or debris. Make sure that the seat is clean.
Lubricate the new o-ring for the seal seat with a
Rotary
Stationary
Elastomers
Viton
Carbon
Viton
Silicon
Silicon
Carbide
Carbide
Carbide
Viton
Sil/Carbide
Afl as
EPR
EPR
11

Publicidad

Tabla de contenido
loading

Tabla de contenido