2
Parametering your SGA/AXOVIA
I The steps:
J Presentation of the symbols.
J Parametering your SGA/AXOVIA.
J Using precautions for the automatic mode.
J Securization of parametering.
J Presentation of the symbols.
Long press
over 0,5 seconds
Short press
under 0,5 seconds
J Memorising remote controls
Before starting the parametering your installation, check that the ON/OFF and PROG
lights are lit and the DANGER
light is off.
Do the following operations :
G
Functioning of the remote controls :
Your SGA /AXOVIA can function with one or several remote controls. The
operations described below must be repeated as often as there are remote controls
to memorize.
Your SGA / AXOVIA offers 2 different mode of
functioning :
Total opening only
Systematic total opening of the 2 leaves per short
or long press on remote control.
Pedestrian opening or total opening
Opening of only one leaf for pedestrian access by short press
on the remote control.
Total opening of the 2 leaves per long press on
remote control.
Blinking light
Lit light
2
Parametering your SGA/AXOVIA
G
Memorising the remote controls in total opening only :
Choose key of remote control which you wish to use to order your gate.
Place remote control against the target engraved on the hood:
Maintain button to be memorized
1
pressed until the PROG light blinks slowly
(the DANGER
light lights up during
this operation)
2
Release button : it is memorized.
G
Memorizing remote controls in pedestrian or total opening:
Choose key of remote control which you wish to use to order your gate.
Place remote control against the target engraved on the hood:
Maintain button to be memorized
1
pressed until the PROG light blinks slowly
(the DANGER
light lights up during
this operation)
2
Release button
Again press (before 10 seconds) on key to memorize until PROG light blinks slowly (the
3
light DANGER
lights during this operation).
4
Release button : it is memorized.
At the end of the memorization cycle, only the PROG and ON/OFF lights are lit,
the electronics waiting for memorization of leaf displacement
G
Change of operating mode of the already memorized remote controls:
To switch remote control from "opening total" mode to "opening pedestrian or total"
memorize remote control as mentioned above "memorizing of the remote controls in opening
pedestrian or total" . Last memorizing erases the preceding memorized mode. To switch
remote control from "opening pedestrian or total" mode to "opening total" mode, memorize
remote control as mentioned above "memorizing of the remote controls in total opening".
Last memorizing erases the preceding memorized mode.