CONTROLLER PROGRAMMING INSTRUCTIONS (cont)
Alarm
The controller comes from the factory with the alarm
function disabled. To utilize the alarm function set the
desired band and sensitivity.
Band
Hold the 56 buttons simultaneously for 3 seconds to
enter the program mode. Press the 6 button once.
The display should now read level 1. Hold the Ý button
and press the 5 button once to get to level 2. Press
the 5 button 5 times until the display reads SP2.A and
blinks none. Hold the Ý button and press the 5 button
three times. The display should now read band. Hold
the 56 buttons simultaneously for 3 seconds to exit
the program mode. The alarm function is now active.
Sensitivity
Hold the 56 buttons simultaneously for 3 seconds to
enter the program mode. Press the 5 button eleven
times. The display should now read SET.2. Hold the Ý
button and press the 5 button to desired alarm band
width. Hold the 56 buttons simultaneously for 3 sec-
onds to exit the program mode. The alarm is now set.
Note: If the temperature goes outside of the Alarm tem-
perature band after reaching set point, the alarm will
activate. The alarm is indicated by a flashing red light
on the bottom right of the face and the display will blink
-A-.