Forewarning flashing light enabled or disabled.
PRE
Off: disabled forewarning flashing light.
On: enabled forewarning flashing light. The flashing light is activated 3 sec before the motor starts.
The Service Man function is enabled or disabled.
Off: Automatic operation.
htr
On: Service Man operation.
The OPEN/CLOSE push-buttons should be kept pressed for the entire operating time.
The lock function is enabled or disabled.
Off: Lock function disabled.
On: Lock function enabled. After the triggering of the closure limit switches, the control
BLC
unit delays the stop by approx. 0.5sec in order to allow a better resting of the gate leaf
onto the stoppers. DAS input is activated in the closing phase only.
Note: In case of sliding gates, leave to OFF.
Enables or disables the absolute Encoder input (ENC ASS connector).
Enc
On: Motor with absolute Encoder.
Off: Motor with no absolute Encoder.
Auxiliary capacitor
disg
On: 230Vac motor - single-phase and Auxiliary capacitor (terminal 7/8)
Off: 400Vac motor - Three-phase .
Photocell 1 input in the opening phase is enabled or disabled.
Pho1
On: Photocell 1 is activated in the closing phase only.
Off: Photocell 1 is activated in both opening and closing phases.
Photocell 2 input in the opening phase is enabled or disabled.
Pho2
On: Photocell 2 is activated in the closing phase only.
Off: Photocell 2 is activated in both opening and closing phases.
Photocell 3 input in the opening phase is enabled or disabled.
Pho3
On: Photocell 3 is activated in the closing phase only.
Off: Photocell 3 is activated in both opening and closing phases.
Photocell 4 input in the opening phase is enabled or disabled.
Pho4
On: Photocell 4 is activated in the closing phase only.
Off: Photocell 4 is activated in both opening and closing phases.
Activates or deactivates the photocell test connected to the PHOT1 input
Prior to performing the operation, the unit checks the switching of the photocell contact.
tst1
If the check fails, the operation does not start.
On: photocell test activated.
Off: photocell test deactivated.
tst2
As with TST1 but refers to PHOT2 input
tst3
As with TST1 but refers to PHOT3 input
tst4
As with TST1 but refers to PHOT4 input
(Enables or disables remote radiotransmitters learning, as indicated in the paragraph "Remote
transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the pedestrian opening function
(see parameter TPED).
ped
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested.
RTR
By selecting this function the receiver goes into waiting (Push) for a new PGM pressure to confirm the operation.
At end of erasing the OK message is displayed
16
(
)
RADIO
RADi
FUNZIONE
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)