SPEECH UNIT ART. 68TU/K93
Description
Art. 68TU/K93 is an audio speech unit for use with 2-Wire video kits. It is
equipped with an input which allows the connection of an outdoor CCTV ca-
mera. It can only be fitted to Art. 13K1 entrance panels in the 1300 series.
Speech unit (Art. 68TU/K93) technical specifications
- Operating temperature from - 5° to + 45° C.
- Subject lighting by means of infrared LEDs
- Name-tag lighting through LEDs
- Built-in speech unit
- Removable terminal block
- Input for video signal from an outdoor camera.
- Monitor call push-button.
- Output for control of lighting floodlight by relay type 0170/101
-
Local door release control from entrance panel.
-
Adjustable lock activation time (from 0 to 30 seconds).
- Supply voltage from the bus.
- External dimensions: 80x120x25 mm.
Speech unit (Art. 68TU/K93) controls
The following controls are located on the back of the speech unit:
External
Internal
Lock activation
volume
volume
Camera terminals type 68TU/K, 68TC/K
CL, M)
Connection for relay type 0170/101 for additional floodlight.
(for switching on illumination in the camera's observation zone)
It is activated for the time the camera is on.
CA, M)
Connection for additional lock push-button.
PA, M)
Connection for "open door" sensor. The sensor must be a nor-
mally open contact which closes when the door is open.
B1, B2)
BUS line
S-, S+)
Output for electric lock supply voltage (12V
V)
Connection for video signal from an outdoor camera.
*
The panel supplies a current peak IT> 1A for 10 mS, followed by a hold
current I
= 200mA for the entire duration of the lock control.
M
Art. 68TC/K, 68TU/K
Camera activation
time
time
*
).
ENTRANCE PANEL/CAMERA identification code
If more cameras/entrance panels are installed on the building it is necessary
to identify the cameras with a different code. The identification code is as-
signed by inserting the jumpers in the contacts as shown on the figure.
12V
LED CH2
Name tag lighting
LED
OPERATING DWELL TIME
The monitor, camera, door lock and auxiliary services mut operate accor-
ding to the following intermittent cycles.
Monitor and camera activation cycle:
max. 90 seconds activated, 90 seconds deactivated
Door lock cycle:
max. 1 second activated, 5 seconds deactivated
Auxiliary service cycle:
max. 90 seconds activated, 90 seconds deactivated
6/32
1st
IT=0
(Default)
2nd camera
IT=1
Name tag lighting
LED
2nd push-button
1st push-button
Microphone
Fig. 1
camera
Fig. 2