Defining profiles
• Editing an existing profile (excluding Leister profiles):
– In the working display (28), set the required setpoints using the «Plus»
– In the function display (27), select the Settings menu
– In the «Setup» menu, select «Save Profile» with the «Plus» key (26)
– Select the profile you want to edit and confirm with the relevant key (25)
– In the function display (27), select the «Edit selected item» symbol
(25)
.
– Enter the desired profile name (see "Entering names or passwords" chapter), then select the
with the «Plus» key (26)
– In the function display (27), confirm the selected «Save» symbol
profile has now been successfully saved and selected.

Machine setup

and confirm with the relevant key (25)
Menu
Function
Setting the unit used:
Select Unit
– metric/imperial
LED mode:
– ON*: The LED light can only be switched on if the drive is
released. As soon as the drive is released, the LED symbol
appears in the function display (27). This symbol allows you
to switch the LED light on/off as you wish. The LED mode is not
changed.
LED Mode
– ON: The LED light is permanently switched on.
The LED symbol
This symbol allows you to switch the LED on/off as you wish.
The LED mode is not changed.
– OFF: The LED light is permanently switched off.
LCD Contrast
Setting the LCD contrast
LCD Backlight
Setting the backlight for the display
Key Backlight
Setting the backlight for the keyboard
or «Minus»
with the «Plus» key (26)
.
.
and confirm with the relevant key
.
with the relevant key (25)
is displayed in the function display (27).
keys (24/26).
.
symbol
. The