Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SC 600 II
9. LED indicate
a.
LED of Power indicated the input power.
b. LED of LEARN indicated the transmitter learn status.
c.
LED 1 indicate the 'CLOSE' external button, if the button is pressed the LED will light.
d. LED 2 indicate the 'OPEN' external button, if the button is pressed the LED will light.
e.
LED 3 indicate the 'STOP' external button, if the button is pressed the LED will light.
f.
LED 5 indicate the 'O/S/C' external button, if the button is pressed the LED will light.
g. LED 6 indicate the 'pedestrian switch' external button, if the button is pressed the LED will light.
h. LED 7 indicate the 'infrared sensor' status, if the output is connected the LED will light.
i.
LED 9 indicate the 'Loop detector' status, if the output is connected the LED will light.
j.
LED 10 indicate the 'Close limit switch' status, if the switch is connected the LED will light.
k.
LED 12 indicate the 'Open limit switch' status, if the switch is connected the LED will light.
10. Maintenance
Check the door once a month. The door should be carefully checked for balance. The door must be in good working
order.
We suggest for safety reasons, photocells be used on all gates.
Disconnect from mains supply before replacing bulb.
Be sure to read the entire manual before attempting to perform any installation or service to the door operator.
Our company reserves the right to change the design and specification without prior notification.

11. Troubleshooting

Trouble
Possible causes
The door fails to open
1. Power is OFF
and close. LED display
2. Fuse burn
does not light.
1. Infrared beam is
obstructed.
The door can open
2. Infrared sensor function is
fails to close.
enabling, but the sensor has
not been installed.
Remote transmitter
1. Battery level may be low
does not work.
2. Transmitter code is lost
The transmitter
operating distance is
Battery level may be low.
too short.
12. Packing list
After receiving the gate operator, you should make an unpack-inspection, in which you should check whether the product was
damaged. If you have any problem please contact our dealer. You should find the following items in our standard packing:
Solutions
1. Make sure that power is ON.
2. Replace fuse.
1. Remove obstructions.
2. Make sure the infrared sensor
function is disabling.
1. Replace the battery inside the
transmitter.
2. Reprogram the transmitter.
Replace battery.
No.
Item
SL600AC sliding gate
1
operator
Release key
3
User's manual
4
https://appceso.com
Quantity
1
2
1
40

Publicidad

loading

Este manual también es adecuado para:

Sc600acSc600acu