TROUBLESHOOTING

The motor does not start.
• Check the motor power supply.
• The remote control indicator light remains off; the battery is flat, replace it.
• Check that the motorisation has not been disengaged, re-engage it.
• Check that the photoelectric cells are neither obstructed nor dirty.
• This type of motorisation is unsuitable for intensive use. The software thermal protection may activate.
If the problem cannot be fixed, please contact the motorisation installer.

TECHNICAL SPECIFICATIONS

Power supply
Motor power supply
Motor revolutions
Power consumption
Maximum consumed current
Capacitor
Thermal protection
Insulation category
Reduction ratio
Revolutions at output
Pinion
Gate speed
Maximum weight of the gate
Maximum torque
Lubrication
Manual manoeuvres
Obstacle detection
Number of cycles/day
Control unit
Backup batteries (optional)
Operating temperature
Index protection rating
Weight
Accessories power supply
Automatic closure time
Operating time
Pedestrian opening time
Reversal pause
Integrated flashing amber light connection
Fuses
Built in radio receiver
Number of memorizable remote controls
RTS remote control frequency
Aerial resistance
4
MOTOR
Elixo 500 24 V
230 V +10%, 50 Hz
24 Vdc
3500 rpm
70 W
0.5 A (23 Vac) - 1 A (110 Vac)
/
/
/
1/44
79 rpm
4 mm module (14 teeth)
12 m/min
500 kg
20 Nm
Permanent grease
Mechanical release with handle
Electronic torque limiter
30
Built in with LCD display
Two 12 V 1.2 Ah batteries
-15 °C to +60 °C
IP24
7 kg (~ 70 N)
ELECTRONICS
24 Vac (180 mA)
between 3 and 120 seconds
120 s
7 seconds (fixed)
1 second approximately
24 V maximum 25 W
250 V T 0.62 A and T 1 A
RTS
36
433.42 Mhz
50 Ohm (RG58)
Elixo 500 230 V
230 V +10%, 50 Hz
230 Vac
1400 rpm
290 W
1.5 A (230 V) - 3 A (110 V)
10 μF (230 V) - 40 μF (110 V)
110°C
F
1/30
48 rpm
4 mm module (14 teeth)
8.5 m/min
500 kg
20 Nm
Permanent grease
Mechanical release with handle
Friction clutch
100
Integrated
/
-15 °C to +60 °C
IP24
15 kg
24 V (0.2 A maximum absorbed)
between 0 and 90 seconds
between 0 and 120 seconds
7 seconds (fixed)
1 second approximately
230 V maximum 15 W
250 V T 0.62 A and T 1 A
RTS
36
433.42 Mhz
50 Ohm (RG58)
Copyright © 2008 Somfy SAS. All rights reserved.