CLEARING REMOTE CONTROLS AND ALL SETTINGS

Clearing remote controls

Press the "PROG" button until the light blinks (7 s).
This clears all of the remote controls memorised.

Resetting all settings

Press the "SET" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default values.

LOCKING PROGRAMMING

Used to lock the programming settings (end limit setting, self-learning, setup).
Simultaneously press the "SET", "+" and "-" buttons:
- start by pressing "SET".
- pressing "+" and "-" must take place within two seconds.
To access programming mode once again, repeat the same procedure.

REFITTING COVERS

Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in one of the two positions shown in Figure 41.

TROUBLESHOOTING

Operating codes displayed

Code
Description
C1
Waiting for a command
C2
Door opening
C3
Waiting for the door to close
C4
Door closing
C5
Obstacle detection
C6
Safety input active
C9
Pedestrian door safety contact active
Ca
Safety mechanism self test
Cb
Permanent hardwired control
Cd
Working from back-up battery
Waiting for a command

Programming codes displayed

Code
Description
S1
Awaiting setting
S2
Learning mode
F0
Awaiting remote control memorisation for
operation in total opening
F1
Awaiting remote control memorisation for
operation in partial opening
F2
Awaiting remotely controlled lighting
memorisation
Fig.
38
Fig.
39
(Fig. 40)
(Fig. 41)
Comments
Displayed during obstacle detection then for 30 s.
Displayed after a movement request or during movement, when the safety input is active.
This display is maintained as long as the safety input is active.
Displayed after a movement request or during movement, when the pedestrian door contact is open.
The display is maintained as long as the pedestrian door contact remains open.
Displayed during safety mechanism self tests.
Indicates that the permanent hardwired control input is activated (contact closed). Commands from radio
remote control units are inhibited.
Comments
Pressing the "SET" button for 2 s starts the learning mode.
Pressing the "OK" button starts the learning cycle: the S2 display blinks during the entire cycle.
Pressing the "+" or "-" buttons will control the motor in forced mode.
Pressing a button on the remote control allocates this button to the motor total opening control.
Pressing "PROG" once more switches to "awaiting remote control memorisation for operation in partial opening:
F1" mode.
Pressing a button on the remote control allocates this button to the motor partial opening control.
Pressing "PROG" once more switches to "awaiting remotely controlled lighting memorisation: F2" mode
Pressing a button on the remote control allocates this button to the remotely controlled lighting control.
Pressing "PROG" once more switches to "awaiting remote control memorisation for operation in total
opening: F0" mode.