(FOR INSIDE WALL MOUNTING)
THREAD INFEED FROM VIA SYSTEM WALL
NOTE: Connect Thread floor system to building power source only, not to VIA power.
To infeed power to a Thread system, externally, from a VIA wall system, refer to
power infeed information on pages 7 & 8.
NOTE: When a Thread floor system is used with a VIA wall system, the Thread floor
system must be completed prior to the VIA product installation. The connection of
power to the Thread system from a power source inside a VIA wall must be carefull-
planned and coordinated to properly interface the power components of the two systems.
NOTE: When infeeding power, internally, from a VIA wall into a Thread power
system, the entry point must be from a VIA junction post that is not adjacent to a door
frame, a corner or a finished end.
CONNECTING THE POWER TRACK
• At the base of the junction post, where the infeed power track will access the VIA
junction post, cut and remove a section of the vertical base trim as noted (View 1).
• Align the wall junction with the housing of the power track infeed. Connect the track
infeed to a building power source per all applicable codes (View 2).
NOTE: Junction trim cover length must be cut to extend completely to floor to cover
trimmed base open gap. Before installing junction trim cover, remove approximately 3
inches off flanges on inside of cover, as noted, for clearance (View 3).
VIEW 1
VERTICAL BASE TRIM
IN-LINE
JUNCTION
POST
REMOVE
FROM FLANGES
LOCATE LEVELERS
OUTSIDE OF JUNCTION
POST
BULDING
POWER
SOURCE
CONNECTION
VIEW 2
JUNCTION
TRIM
COVER
VIEW 3
VIA POWER COMPONENTS
ARE NOT ALLOWED IN
JUNCTION POST WITH
THREAD INFEED
BULDING POWER
SOURCE INFEED
POWER
TRACK
INFEED
CUT TRIM COVER LONGER
TO EXTEND COMPLETELY
TO FLOOR
Page 10 of 75
24207101 Rev G