(FOR FLOOR MOUNTING)
POWER TRACK INFEED INSTALLATION
•
Arrange power infeed track and two (2) lower housings, as shown. Assemble housings to track, engaging plastic end bracket and locking tab (View 1).
NOTE: Floor box must be a sealed, listed box & cover and use included wire connector seal to prevent water intrusion into the box.
NOTE: Floor track infeed is not a splice box.
• Place power infeed track in final position, using hole in assembled lower housings to align track with access hole in floor electrical box cover plate. Fasten power
infeed track to floor, then remove assembled lower housings from installed track and remove electrical box cover plate (View 2).
NOTE: End of the infeed track must not be blocking removal of electrical box cover plate.
• Assemble the supplied wire seal to the electrical box cover plate, as shown. Make sure that the assembled seal is no higher than 3/8" (9.5mm) above top surface
of cover plate. Secure wire seal to cover plate with the thin hex nut (View 3).
• Route infeed track wires through the wire seal. Leave enough wiring slack to route wires through wiring tabs, as shown (View 4).
• Make all hardwire connections and tighten clamp nut to secure wires. Secure cover plate to electrical box.
• Reassemble lower housings to infeed track and route wiring as noted (View 5).
NOTE: The ground fault curcuit interrupter (GFCI) device can not be located in the floor box using this method.
FLOOR INFEED TRACK
PLASTIC END
BRACKET
VIEW 2
ELECTRICAL BOX COVER PLATE
VIEW 1
LOWER HOUSINGS
DO NOT COVER ELECTRICAL
BOX COVER PLATE WITH END
OF INFEED TRACK
ELECTRICAL BOX
ELECTRICAL BOX
3/8" MAX
ALLOWABLE
HEIGHT
TIGHTEN CLAMP NUT
NOTE: All wires must have
insulation not damaged or
impaired in any way where
contacting seal in connector.
WIRING TAB
VIEW 5
COVER PLATE
WIRE SEAL
ASSEMBLED VIEW
WIRING TAB
THIN HEX NUT
VIEW 3
O-RING
CLAMP NUT
VIEW 4
Page 11 of 75