Connecting The Water Lines - LG TCW2013QS1 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connecting the water lines

1
Check the rubber seals on both sides of the
hose.
- Insert a rubber seal into the threaded
fittings on each hose to prevent leaking.
Rubber seal
Water hose
(To water inlet on the
washing machine)
2
Connect the water supply hoses to the HOT
and COLD water faucets tightly by hand and
then tighten another 2/3 turn with pliers.
- Connect the blue hose to a cold water
faucet and the red hose to a hot water
faucet.
WARNING
• Do not overtighten. Damage to the
coupling can result.
3
After connecting inlet hose to water
faucets, turn on the water faucets to flush
out foreign substances (dirt, sand, sawdust)
in the water lines. Let water drain into a
bucket, and check the water temperature.
4
Connect the hoses to the water inlets tightly
by hand and then tighten another 2/3 turn
with pliers.
Rubber seal
water inlet
Water hose
(To faucet)
• Do not overtighten the hoses.
Overtightening can damage the valves
resulting in leaking and property damage.
5
Check for leaks by turning on the faucets.
• For your safety, and for extended product
life, use only authorized components.
The manufacturer is not responsible for
product malfunction or accidents caused
by the use of separately purchased
unauthorized parts.
• Use new hoses when you install the
washing machine. Do not reuse old hoses.
Use only the inlet hoses provided with the
washer. LG does not recommend the use
of aftermarket hoses.
• Periodically check the hoses for cracks,
leaks and wear, and replace the hoses
every 5 years.
• Do not stretch the water hoses
intentionally, and make sure that they are
not crushed by other objects.
• Water supply pressure must be between
20 PSI and 120 PSI (138~827 kPa). If the
water supply pressure is more than 120
PSI, a pressure reducing valve must be
installed.
• To provide optimum washing performance
the hot water temperature should be set
at 120-135°F (48-57°C) and the cold at
60°F (15°C).
INSTALLATION INSTRUCTIONS
- Connect the blue hose to the cold water
inlet and the red hose to the hot water
inlet.
Cold
WARNING
- If water leaks, check steps 1 to 4 again.
NOTE
13
Hot water
inlet