Programming Mode - Test Mode - LG TCW2013QS1 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

62

PROGRAMMING MODE - TEST MODE

PROGRAMMING MODE - TEST MODE
Diagnostic tests:
This program has been added for testing the washer and detecting errors.
Entering the test mode
Data Name
Button
Entering
1. Entering
the test
programming mode
mode
2. Hot
3. Start
1.
According to pressing Start button, test move to the next step.
Number of times
the Start button is
pressed
None
1 time
Turns on all lamps and locks the door Displays 1U:XX, 1t:XX and 12:XX alternately (Version)
2 times
Tumble Clockwise.
3 times
Low Speed Spin
4 times
High Speed Spin
Inlet valve for cold water turns on.
5 times
(Close the gravity drain valve.)
6 times
Inlet valve for hot water turns on.
7 times
Inlet valve for atomizing turns on.
8 times
Inlet valve for bleach turns on.
Tumble counter clockwise.
9 times
(Open the gravity drain valve.)
10 times
Turn on Circulation Pump.
11 times
Drain Pump turns on.
12 times
Turn on the heater
13 times
Turns on all lamps.
14 times
Button Checks.
15 times
High Speed Spin
16 times
17 times
NOTE
• Make sure the drum is empty when a diagnostic test is performed. Do not use
(display)
Display
Insert service card (card type), turn on/off toggle switch
(Coin type).
Press the Hot button. Then
Enter the diagnostic test mode.
Check Point
PDA Signal Check
Description
Display
rpm (42~50)
rpm (550~650)
rpm (900~1000)
Water level frequency (255~)
Water level frequency (255~)
Water level frequency (255~)
Water level frequency (255~)
rpm (42~50)
Water level frequency (255~)
Water level frequency (255~)
Displayed XX
Displays 1U:XX, 1t:XX and 12:XX alternately
rpm (900~1000)
this function is not applied in this machine
appears in the display.
.