Cables
KMTRE−ST42−5
KMTRE−ST42−10
KMTRE−ST42−x
Plug connectors and their pin assignments
Pin no.
1
2
Pin no.
3
4
5
6
7
8
9
Connecting the cable
Please note
Connection to the main power supply and the fitting of mains switches, trans
formers, fuses and mains filters may only be carried out by a qualified elec
tronics engineer.
Festo MTRE−ST42−48S−.. 0407a English
Designation
Motor cable 5 m
Motor cable 10 m
Motor cable x m (up to max. 10 m)
Function
Function
MTRE−
MTRE−
ST42−48S−A A
ST42−48S−AB
+24 ... 48 V DC
+24 ... 48 V DC
Dir (Direction)
Dir (Direction)
+5 V
+5 V
Function MTRE−ST42−48S−A A
Clk (pulse) +5 V
Clk (pulse) +24 V
GND
Dir (direction)
Dir (direction) +24 V
Clk (pulse)
NC
Fig. 10
Function MTRE−ST42−48S−AB
Clk (pulse) +5 V
Clk (pulse) +24 V
GND and brake
Dir (direction)
Dir (direction) +24 V
Clk (pulse)
Brake +24 V
39