RIB S1 fw.04 Manual Del Usuario página 23

Cuadro electonico de mando para un motor monofasico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

POINT B
- SETTINGS
DIP 1
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
PROGRAMMING (See Point D)
DIP 2-1 PROGRAMMING OF PEDESTRIAN OPENING (See Point E)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Radio receiver STEP BY STEP
OFF - Radio receiver AUTOMATIC
DIP 5
ON - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
OFF - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
DIP 6
ON - Photocells active only in closing
OFF - Photocells always active
DIP 7
ON - Encoder enabled for PLUS operator
OFF - Encoder disabled
DIP 8
ON - Blinker pre-flashing
OFF - Blinker normal flashing
DIP 9
ON - Low speed in approaching DISABLED
OFF - Low speed in approaching ENABLED
DIP 10 ON - Electronic brake ENABLED (HARD brake, only for
FAST operators)
OFF - Electronic brake DISABLED (SOFT brake, only for
FAST operators)
DIP 11 ON - Gradual start ENABLED
OFF - Gradual start DISABLED
DIP 12 ON - Safety strip self test ENABLED
OFF - Safety strip self test DISABLED
DIP 13 ON - Motor operation control by external power relays (only
for S1/R2 and S1/R4 control boards). Encoder, low
speed in approaching, gradual start and electronic
brake features, low speed and torque regulator will be
automatically disabled regardless their dip-switches and
trimmers position.
OFF - Standard motor operation control without power relays
DIP 14 - selection of motor-type (see chart)
DIP 15 - selection of motor-type (see chart)
DIP 16 - selection of motor-type (see chart)
CHART 1
DIP 14
DIP 15
DIP16
MOTOR TYPE
OFF
OFF
OFF
K800 - K800 PLUS
ON
OFF
ON
K800 FAST
ON
OFF
OFF
K1400 - K1400 PLUS
OFF
ON
OFF
K2200 - K2200 PLUS
ON
ON
OFF
SUPER 2200
OFF
OFF
ON
SUPER 2200 FAST
OFF
ON
ON
SUPER 3600
ON
ON
ON
SUPER 3600 FAST
DIP 17 ON - close command after the transit through the photocell
ENABLED
OFF - close command after the transit through the photocell
DISABLED
DIP 18 ON - Working with motors 120V 60Hz
OFF - Working with motors 230V 50-60Hz
LED WARNINGS
DL1 - programming activated (red)
DL2 - stop contact NC (red)
DL3 - open limit-switch contact (red)
DL4 - close limit-switch contact (red)
DL5 - photocell contact (NC) (red)
DL6 - gate opening (green)
DL7 - gate closing (red)
DL8 - safety strip contact (NC) (red)
DL9 - Encoder output state
FUSES
F1 T100mA Fuse for accessories protection
F2 T5A
Fuse for motor windings protection
RELAYS AND MOTOR CONTROL
K1 => Opening command
K2 => Closing command
K3 => Flashing light command
Q5 => TRIAC - Motor command in opening and closing
TORQUE =>TR2 - Electronic regulator for motor torque
Power can be controlled by rotating the TORQUE trimmer – this
changes the output voltage on motor ends (more power is delivered to
the motor by rotating the trimmer clockwise).
Actually, the motor is always turned on at full power regardless the
trimmer position (to guarantee the starting in all the condition) and,
then, after 3seconds, the torque control is activated.
LOW SPEED =>TR1 - Electronic regulator for low speed on
approach
If DIP9 is turned OFF, the low speed on approach can be controlled
by rotating the LOW SPEED trimmer. The low speed is activated when
the gate is 0.50-0.60 meters away from the complete closed or open
position.
ELECTRONIC BRAKE
If DIP 10 is turned ON, the electronic brake will activate upon total
opening or closing.
ELECTRONIC BRAKE (For FAST operators)
If DIP10 is turned ON, a HARD electronic brake will be active.
If DIP10 is turned OFF, a SOFT electronic brake will be active.
GRADUAL START
If DIP11 is turned ON, a gradual movement will be enabled for 1second
upon each starting.
In case of an obstacle is detected by any safety inputs (photocell, safety
strip or encoder), the gradual start is bypassed for the time being to
guarantee a more prompt and safe reaction.
POINT C
- MOTOR ROTATION DIRECTION CHECK
This operation is meant to help the installer during the installation and
for further future controls.
1 - Unlock the operator with the Manual Release, slide the leaf open
about halfway and lock the operator again.
2 - Turn DIP1 to ON position, LED DL1 starts blinking
3 - Press and hold the PROG.Button, the gate will open or close.
Release the button and the gate will stop. Press and hold again, the
gate will move in the opposite direction.
The S1 control board has two movement leds
- DL6 the GREEN led for OPENING
- DL7 the RED led for CLOSING
When you press and hold the PROG.Button, if the gate opens with
the green led on then you may proceed to step 4.
If the gate moves in the wrong direction compared with the
movement leds:
- turn OFF the main AC power
- reverse the V and W motor cables position (the blue motor cable
must be always in the U position)
- reverse the limit switch wires marked LSO and LSC
- turn ON the main AC power and check again the motor direction
4 - After 3seconds (2 for FAST operator) motor starting and for the
next 10 seconds (6 for FAST operator) motor working, the torque
control is automatically activated. Set the motor torque by the
TORQUE Trimmer which varies the output voltage to the head of
23
23
G
B

Publicidad

Tabla de contenido
loading

Tabla de contenido