Electric Connections - V2 HYPERFOR 4000 Manual Del Usuario

Motor electromecanico 400v, irreversibles a cremallera, para puertas correderas, hasta 4000 kg de peso
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7 - ELECTRIC CONNECTIONS

TOP BOARD
Antenna shielding
A1
Antenna
A2
ING1 - configurable input to connect devices with
N.O. contact
S1
parameter
ING1
DEFAULT =
START
ING2 - configurable input to connect devices with
N.O. contact
S2
parameter
ING2
DEFAULT =
ST.PE
ING3 - configurable input to connect conventional
devices with N.O. contact
S3
parameter
ING3
DEFAULT =
(no function)
NO
Common (-)
S4
Photocell 1. N.C. contact
S5
parameter
FOT1
DEFAULT =
(no function)
NO
Photocell 2. N.C. contact
parameter
S6
FOT2
DEFAULT =
CFCH
closed gate)
Safety ribb. 1. N.C. contact
S7
parameter
COS1
DEFAULT =
(no function)
NO
Safety ribb. N.C. contact
S8
parameter
COS2
DEFAULT =
(no function)
NO
Common (-)
S9
Closing limit switch. N.C. contact (PRE-WIRED)
H1
Opening limit switch. N.C. contact (PRE-WIRED)
H2
NOT USED
H3 - H4
Common (-)
H5
- Open gate warning light
- 24Vdc blinker
H6*
parameter
SPIA
DEFAULT =
W.L.
- Common open gate warning light
H7
- 12Vdc common power supply
12Vdc power supply
H8
24Vac accessory power supply
E1 / E2
Common accessories power supply
E3 / E4
Photocell TX power supply (24Vac) for Functional test
E5
Emergency STOP
T1 - T2
(activates the cycle)
(partial opening)
(enabled when closing and with
(open gate warning light)
LOWER BOARD
MOTOR
Motor (PRE-WIRED)
U3-U2-U1
REL2 relay options
OUTPUT
Z6-Z5
REL2
DEFAULT =
REL1 relay options
OUTPUT
parameter a
Z4-Z3
REL1
DEFAULT =
OUTPUT
230V - 40W blinker
Z2-Z1
Ground terminal for connection of the ground
W1-W2
system and the motor
W3-W4-W5 Three-phase power supply network
OTHER
F2A - 500V. Power fuse
F1
F250mA. Flashing lamp fuse
F2
F1A. Brake fuse
F3
ADI interface
ADI
MRx receiving modules
RECEIVER
It indicates that the control unit is powered
MAINS
It indicates a 24Vac power overload of
OVERLOAD
accessories
* H6 : H6 terminal can be used for connecting a gate open
warning light or a blinker to 24Vdc.
Configure the
parameter depending on the device
SPIA
connected
m
WARNING: The installation of the unit, safety devices
and accessories must be carried out when the power supply
is disconnected.
m
WARNING: connect the grounding system to the
ground terminal W2
- 40 -
parameter a
(no function)
NO
(courtesy lights)
LUCI

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hyperfor

Tabla de contenido