ELECTRICAL CONNECTIONS

• Unscrew "A", pull the connector out of the motor, remove
the gasket "B", open the connector levering with a
screwdriver in the slot "C" provided for this purpose.
• As regards 230 V BINGO and 120 V BINGO installed on the
right swing, please connect the terminals as follows:
1 Closing cable,
3 Common cable
2 Opening cable,
• 24 V BINGO require connection of the connector terminals
no. 1 and no. 2 with the control unit terminals + and –.
Remember to connect the earth wire with the terminal.
• As regards BINGO installed on the left leaf invert
cables on terminals no. 1 and no. 2.
• Replace the gasket "B", insert the connector, bolt the screw
"A", and check the correct functioning of the automation.
WARNING:
• Always remember to connect the earth according to current
standards (EN 60335-1, EN 60204-1).
• Do not use cables with diameter above 10 mm.
• If the feeder is damaged, a replacement must be effected
from licensed and qualified personnel.

EMERGENCY RELEASE

In case of a blackout, the gate can be operated directly from the
motor. Insert the key supplied in the lock, per--form 1/4 of a turn
and open the plastic door completely. To restore the automation,
simply close the door, rotate the key in closed position and slide
the specially provided plastic cover onto the lock.
Earth wire
12