At this point, to start the cycle press the START icon.
To stop the cycle, press the START icon again.
If the temperature detected by the probe reaches the blast chilling end value within the maximum expected dura-
tion, the cycle will be considered correct and the blast chiller will automatically go to the conservation phase
When switching from blast chilling to conservation phase, the buzzer is activated for a set time.
If the temperature detected by the probe does not reach the blast chilling end value within the maximum expected
duration, blast chilling will not be completed correctly but will continue.
The buzzer will be activated.
If the temperature control has been selected, the system starts a test to verify the correct insertion of the probe.
If the test is successfully completed the cooling cycle will start; otherwise a time-controlled cooling cycle will be
started (in this case, the probe icon is deactivated and the time icon is activated).

5.3 DEEP FREEZING AND CONSERVATION

Pressing the DEEP FREEZING icon on the main screen,
the system shows the screen on the side.
The options are the same as on the BLAST CHILL screen:
• Deep freezing with probe control
• Deep freezing with time control.
In both cases, at the end of the deep freezing phase the
blast chiller automatically switches to a conservation phase
for an indefinite time.
The system also proposes the choice between:
• Hard deep freezing (proposed by default)
• Soft deep freezing
The hard cycle is divided into the following phases:
• deep freezing
• conservation
The soft cycle is divided into the following phases:
• soft deep freezing
• deep freezing
• conservation
At this point, to start the cycle press the START icon.
To stop the cycle, press the START icon again.
If the temperature control has been selected, the system starts a test to verify the correct insertion of the probe.
If the test is successfully completed the cooling cycle will start; otherwise a time-controlled cooling cycle will be
started (in this case, the probe icon is deactivated and the time icon is activated).