A) Memorising a channel (fi g.12):
1. Press and hold down button "P3" MEMO: The LED "L2" will
fl ash slowly.
2. At the same time activate the transmitter which is to be memorised.
3. Hold down button "P3" MEMO until LED "L2" starts to fl ash again.
4. Release the button: The LED will continue to fl ash.
5. Activate the transmitter again (same transmitter, same channel; if the
channel is different or it is a different transmitter the memorisation
attempt will abort without success)
6. End of memorisation: The LED "L2" will remain lit for 2 seconds,
indicating that the transmitter has been correctly memorised.
Note:
• It is not possible to memorise a code which is already in memory:
if you attempt this, the LED will switch off when you activate
the transmitter (point 2).
Only after releasing the button "P3" MEMO will you be able to
continue the memorising procedure.
• If after activating the transmitter for the fi rst time you wait for more
than fi fteen seconds without activating the transmitter a second time
the memorisation attempt will abort without success.
B) Cancelling a channel (fi g.12):
1. Press and hold down the button "P4" DELETE: The LED "L2"
will fl ash quickly.
2. Activate the transmitter channel which is to be cancelled.
3. The LED "L2" will remain lit for 2 seconds, indicating that the
transmitter has been cancelled.
Note:
• If the user that you wish to cancel is not in memory, The LED will
stop fl ashing; Only after releasing the button "P4" will you be able
to continue the cancellation procedure.
• For both the memorisation and cancellation procedures, if
the button is released before activating the transmitter the
procedure will abort.
C) Cancelling all user codes from memory (fi g.12):
1. Keep both buttons pressed down ("P3+P4") for more than
four seconds
2. LED "L2" will remain lit during the entire cancellation time
(about 8 seconds).
3. LED "L2" switches off when the cancellation procedure has
terminated.
Note: When the memory is almost full the time required to search
for a user code could take up to 1 second from when the command
was received. If led "L2" remains alight memory is completely
full. To memorise a new transmitter you will fi rst have to cancel
a code from memory.
D) Memorising ulterior channels via radio
• Memorisation can be activated by radio (without opening the receiver
container) if jumper "J1" has been inserted (fi g.12).
1) Make sure that the jumper "J1" has been inserted (fi g.12).
2) Using a transmitter, in which at least one channel button "A,B,C or
D" has already been memorised in the receiver, press the button
on the transmitter as shown in fi gure.
Note: all the receivers within range
when the channel button is pressed
(and which have at least one of
the transmitter channel buttons
memorised) will activate their signal
buzzer "B1" (fi g. 12).
3)
Press one of the channel buttons on
the same transmitter. The receivers which do not contain that
channel code will sound a fi ve-second long "beep" and will
then disactivate. The receivers which contain the channel
code will sound a one-second long "beep" and will enter the
programming mode.
4) Press the previously chosen channel buttons on the transmitter
which you wish to memorise; the receiver will sound 2 "beeps"
of half a second each after which the receiver will be ready to
receive another code.
5) To leave the programming mode wait for 5 seconds without
pressing any buttons. The receiver will sound a fi ve-second long
"beep" and will then exit the programming mode.
• When the memory is entirely occupied the buzzer will sound 10
rapid "beeps" and will automatically leave the "programming via
radio" mode. Led "L2" will remain lit on the receiver. The same
signal is given each time you try to enter "programming via radio"
when the memory is full.
CONNECTING THE 433 MHZ MODULE ANTENNA
The receiver is supplied with its own antenna which consists of
a piece of rigid wire 170mm in length. In alternative it is possible
to connect an ANS400 tuned antenna using a coaxial cable RG58
(impedance 50Ω) with a maximum length of 15m.

FUNCTION MODE

1) Automatic
Selected by enabling automatic reclosing (programming step 2,
number
not fl ashing). When the door is completely closed the
opening command will start a complete cycle which will end with
automatic reclosing and the night light switching off.
Automatic reclosing starts after the programmed pause period has
elapsed when the opening cycle has been completed or straight
away after the intervention of a photoelectric cell (the intervention of a
photoelectric cell causes the pause time to be reset).
During the pause time the symbol
pressing the blocking button during this period will stop automatic
reclosing and consequently stop the display from fl ashing.
The intervention of mechanical travel limits will block the door;
The indicator light remains lit until the closing manoeuvre has
terminated
Note: The night light switches on automatically each time a
movement command is given either by control button or by radio.
The intervention of a photoelectric cell during reclosing has noeffect
on the timing of the night light.
2) Semiautomatic
Selected by disabling automatic reclosing (programming step 2,
number
fl ashing).
Work cycle control using separate opening and closing commands.
When the door has reached the completely open position the
system will wait until it receives a closing command either via
an external control button or via radio control, before completing
the cycle.
The activation of one of the travel limit switches causes the door to
stop and the termination of the opening/closing cycle. Starting from
the opening manoeuvre the night light will switch off after the set
period has elapsed. The indicator light remains lit until the closing
manoeuvre has terminated.

ALARM CONDITIONS

1) Parameters loaded from EEPROM are wrong
The letter
, will fl ash on the display and the system remains blocked.
The only way to solve this situation is to enter the program mode and
reprogram the system. If the problem persists after reprogramming,
the problem regards the EEPROM (incorrect memorising). Switch off
the power to the system, after a few seconds switch it back on and
then reprogram the system.
2) Both travel limits have cut in
The letter
, will appear on the display and the system remains
blocked. The warning lights will fl ash for a three second period which
is repeated every six seconds.
The only way to solve this problem is to check the travel limits for
obstacles or damage and then restart the system.
TIMED TRAVEL LIMITS
The work time management allows the system to control the
position of the gate.
During blackouts the programmer will lose the position of the gate
which will be considered to be "completely closed", unless the
completely open travel limit is active this is so as to allow the opening
manoeuvre. The work times are programmed in this transitory phase
in such a way as to guarantee the complete opening of the door and
successively complete closing.
WARNING! For this reason it is extremely important
that you never exclude the travel limits during programming
(step 4 stage 1).
• After repetitive travel inversion manoeuvres, with the motor
stopping then restarting slowly, you may fi nd that the time control
is false and the device does not decelerate before arriving at
the travel limit.
If this happens during closing the travel direction will automatically
invert, but once the door reaches the completely open position
the time control will be reset.
20