Rated Power (two channels):
1200 watts @ 20 Hz to 20 kHz both
channels driven at < 0.1% THD
Rated Power (one channel):
Awaiting test results
Topology:
Class H
Minimum Load Impedance:
@ 70.7 volts
6.3 ohms
Maximum RMS Voltage Swing:
95 volts
Frequency Response:
10 Hz – 25 kHz; +0, -.3 dB at 1 watt
Power Bandwidth:
10 Hz – 50 kHz; +0, -3 dB at rated
power
THD (two channels driven):
<0.008% @ 800 W @ 1 kHz with both
channels driven
THD (one channel driven):
<0.006% @ 830 W @ 1 kHz
SMPTE IMD:
<0.1% 60 Hz and 7 kHz, 800 W @
8 ohms
Slew Rate:
35 V/us
Due to our efforts for constant improvements, features and specifications are subject to change without notice.
ICA
2400V SPECIFICATIONS
Damping Factor:
>250:1 @ 20 Hz – 1 kHz
Input CMRR:
>65 dB @ 1 kHz
Voltage Gain:
x 40 (32 dB)
Input Sensitivity:
1.77 volts
Input Impedance:
20 k ohms, balanced
Hum and Noise:
>-115 dB, "A" weighted referenced to
rated power
Crosstalk:
> -55 dB, "A" weighted referenced to
rated power
Current Draw @ 1/8 power:
497 watts
Current Draw @ 1/3 power:
1037 watts
Idle Current Draw:
35 VA in Standby Mode
Maximum Current Draw:
2,760 VA (time limited by breaker)
Thermal Emissions (BTU/hr.):
940 @ 1/8 power,
1,830 @ 1/3 power
45
Cooling:
120 mm DC fan, off until heatsinks
reach 45° C, then variable speed
Controls:
2 rear panel attenuators, sequential
turn-on /-off:
Indicator LEDs :
2 Clip, 2 Signal, 2 LFC, 1 Protect,
1 Power
Protection:
Temp., DC, turn-on bursts, subsonic,
incorrect load or short
Connectors:
8-pin plugable signal input, 4-pin
plugable sequential power, 4-terminal
barrier strip, IEC AC power connector
Construction:
All steel; 16 ga. chassis, 18 ga. top,
12 ga. rack ears
Dimensions:
5.23" x 19" x 16.4"
133 mm x 483 mm x 416mm
Gross Weight:
51.4 lbs. (23.3 kg.)
Net Weight:
45 lbs. (20.4 kg.)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ica 600Ica 1200Ica 2400Ica 400vIca 800vIca 2400v

Tabla de contenido