Malfunction
The symbol indicat-
ing "Hardware fault"
is displayed.
The symbol indicat-
ing "Documenta-
tion function deacti-
vated" is displayed.
The symbol indicat-
ing "...% of mem-
ory is in use" is dis-
played. (The symbol
appears when the
value is ≥ 90 %.)
20
English
Printed: 10.02.2017 | Doc-Nr: PUB / 5331558 / 000 / 00
Possible cause
A hardware fault has
been identified.
Documentation function
deactivated (warning
only).
Usage of data memory
in the module is indi-
cated in percent. Note:
When 100 % is reached,
the oldest data will be
overwritten!
Action to be taken
▶ Connect the torque
module to a PC.
▶ Use the
PROFIS Adaptive
Torque software to
read out fault memory
and follow the soft-
ware's troubleshoot-
ing instructions.
▶ If you require the doc-
umentation function,
connect the torque
module to the PC and
activate the documen-
tation function in the
PC software
PROFIS Adaptive
Torque.
▶ Where applicable,
press the OK button
to hide the message
and continue the
starting process for
the torque module.
▶ Connect the torque
module to a PC.
▶ Use the
PROFIS Adaptive
Torque software to
read out the data
so that they can be
documented in a
report.
▶ Subsequently delete
the data in the torque
module data memory
in order to clear the
memory for further
use.