Rotary ARO14 Instrucciones De Instalación página 2

Elevador de montaje superficial de cuatro columnas (serie 100) capacidad 14.000 lbs. (7.000 libras por eje
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4'-6" Min. To
Nearest
Obstruction
REAR
Fig. 1
Read and understand these instructions completely before
proceeding with lift installation.
1. Lift Location: Use architects plan when available to
locate lift. Fig. 1 shows dimensions of a typical bay
layout. Lift floor area should be level.
WARNING
DO NOT install on asphalt or other similar
unstable surface. Columns are supported only by anchors in
floor
2. Ceiling or overhead clearance must be 110" plus height
of tallest vehicle.
3. Estimating Column Shim requirements: In the following
section, the terms "highest" and "lowest" refer to
elevation of floor.
transit
Fig. 2
Left Runway
Right Runway
(ARO14 shown)
target
2
A. Mark locations where lift columns will be positioned in
bay.
B. Place target on floor at column positions (NOT on
column base plates) and record readings, Fig. 2.
C. Find the highest of the four locations. Find the
difference between the reading at each of the
remaining three columns and the highest reading.
D. The difference is the estimated amount of shim
thickness needed at each column.
Note: Maximum shim thickness is 1/2" per column using
shims and anchors provided with lift. Shim thickness of 2"
is possible by using optional shim kit and longer anchors.
Contact your authorized Rotary Parts Distribu tor for
ordering information.
Note: Target is positioned on floor at planned col-
umn positions (NOT on column base plates).
Dimension at highest position minus other position
equal shim thickness required
2'–0" Min. To
Nearest
Obstruction
7'-6" Min.
To Nearest
Obstruction
7'-6" Min.
To Nearest
Obstruction
FRONT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Smo14

Tabla de contenido