6.5.

Installing the muting sensors

The muting sensors must allow the protected field to be interrupted
without shutting down the plant by identifying the conveyed material
(pallets, vehicles...), based on length measurements and speed.
Where there are variable transport speeds within the muting area, you
must consider the effect this will have on the overall duration of the
muting process.
Fig. 24 shows an installation example for a PSEN op2/4 safety device
on a conveyor with the relevant muting sensors.
As the package passes through, the ESPE is temporarily suspended
via the muting activation sensors A1, A2, B1 and B2. The outputs on
these sensors are connected to muting inputs 1 (A1; A2) and 2 (B1;
B2) of the receiver on the ESPE.
The contacts for these sensors are monitored via the receiver.
Fig. 24
32