TOOL SPECIFICATIONS
All screws and nuts are metric.
FASTENER SPECIFICATIONS:
TOOL MODEL
SB1850BN
TOOL AIR FITTING:
These tools use a free-flow connector plug, 1/4 N.P.T. The inside diameter should be .200" (5mm) or larger.
The fitting must be capable of discharging tool air pressure when disconnected from the air supply.
OPERATING PRESSURE:
70 to 100 p.s.i.g. (4.9 to 7.0 kg/cm
performance.
DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.
OPERATION
SEQUENTIAL TRIP
The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger. This makes
accurate fastener placement easier, for instance on framing, toe nailing and crating applications.The
Sequential Trip allows exact fastener location without the possibility of driving a second fastener on recoil. The
Sequential Trip Tool has a positive safety advantage because it will not accidentally drive a fastener if the tool
is contacted against the work – or anything else – while the operator is holding the trigger pulled.
MODEL IDENTIFICATION:
Refer to Operation Instructions on page 7
before proceeding to use this tool.
LUBRICATIION
Frequent, but not excessive, lubrication is required for best performance. Oil added through the air line connection will
lubricate the internal parts. Use Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use detergent oil or additives
as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance
and frequent tool maintenance.
If no airline lubricator is used, add oil during use into the air fitting on the tool once or twice a day. Only a few
drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust
cycle.
COLD WEATHER OPERATION:
For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool
operation. We recommend the use of WINTER FORMULA air tool lubricant or permanent antifreeze (ethylene glycol)
as a cold weather lubricant.
CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools
operating valves and mechanisms that could cause tool failure.
NOTE: Some commercial air line drying liquids are harmful to "O"-rings and seals – do not use these low
temperature air dryers without checking compatibility.
BRAD SERIES
GAUGE
BT1300
18
2
). Select the operating pressure within this range for best fastener
SEQUENTIAL TRIP
Identified by:
GRAY TRIGGER
FASTENER RANGE
5/8" - 2"
-4-