Safety Instructions; Loading The Tool - Stanley BOSTITCH N58N58C-1-E Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
70950_CoilNailing_Manual_Update

SAFETY INSTRUCTIONS

IMPORTANT READ CAREFULLY: It is important that all operators read and understand all sections
of this Tool Technical Data manual and the separate Safety and Operating Instruction Manual which come
with this tool. Failure to do so could result in you or others in the working area to be seriously injured.
WARNING! Eye protection in accordance with 89/686/EEC, and with equal or greater grade than
defined in EN166 should be used. However all aspects of operators work, environment and other type/s
of machinery being used, should also be considered when selecting any personal protection equipment.
Note: Non-side shielded spectacles and face shields alone do not provide adequate protection.
WARNING! To prevent accidental injuries:
Never place a hand or any other part of the body in fastener discharge area of tool while the air supply
is connected.
Never point the tool at self or at anyone else.
Never engage in horseplay.
Never pull the trigger unless the nose is directed towards the work.
Always handle the tool with care.
Do not pull the trigger or depress the trip mechanism whilst loading the tool.
To prevent accidental actuation and possible injury, always disconnect air supply.
1. Before making adjustments. 2. When servicing the tool. 3. When clearing a jam. 4. When tool is not in use.
5. When moving to a different work area, as accidental actuation may occur, possibly causing injury.
Read the additional Safety & Operating instructions booklet before using tool.
The operation of this tool can cause sparks and act as a source of ignition for flammable fuels and
gases.
IMPORTANT! Tool Operation:
To identify the operation type of your model, check the ID label affixed to the tool/ rear of this
manualand the corresponding table (marked ?) column L for that model.Read the corresponding
section in the Safety & Operating instructions for information of each trip type.

LOADING THE TOOL

1. Open the magazine: Pull down on the latch and swing the door open. Swing magazine cover open. (Fig. 1)
2. Check adjustment: the nailer must be set for the length of nail to be used. Nails will not feed smoothly if the
magazine is not correctly adjusted.
To change the setting:
The magazine contains an adjustable nail platform on which the nail coil rests. The nail platform can be adjusted
up and down to three or 4 nail settings. To change settings, pull up on the post and twist to the correct step.
(Fig. 2)
N58
1st Step
25mm
2nd Step
30-35mm
3rd Step
38-45mm
4th Step
50/55mm
3. Load the coil of nails: Place the coil of nails over the post in the magazine. Uncoil enough nails to reach the
feed pawl. Place the first nail in front of the front tooth on the feed pawl, in the driver channel. The nail heads
must be in the slot in the nose. (Fig. 3)
7/6/07
17:52
N64
N71
32-38mm
35-45mm
45mm
50/55mm
60-75mm
50/55mm
65mm
80-90mm
65mm
70mm
Page 5
N400
N401
N512
55mm
55mm
75-90mm
60-75mm
100mm
80-90mm
115mm
100mm
100mm
120-130mm
GB
N89C
50-65mm
70-75mm
80-90mm
N/A

Publicidad

Tabla de contenido
loading