Locating The Equipment; Environment; Space Requirements; Mechanical Installation - Parker PNEUDRI MXLE ADVANTAGE Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 227

3.2 Locating the Equipment

3.2.1 Environment

The equipment should be located indoors in an environment that protects it from direct sunlight, moisture, and dust. Changes in temperature,
humidity, and airborne pollution will affect the environment in which the equipment is operating and may impair the safety and operation. It is the
customers' responsibility to ensure that the environmental conditions specified for the equipment are maintained.

3.2.2 Space Requirements

The equipment should be mounted on a flat surface capable of supporting its own weight plus the weight of all ancillary parts. The minimum
footprint requirements are specified below, however there must be adequate space around the equipment to allow airflow and access for
maintenance purposes and lifting equipment. A minimum spacing of approximately 500mm (20 ins) is recommended around all sides of the dryer
and 1000mm (39.4 ins) above it. The pump should have a minimum spacing of 100mm (4ins) around all sides.
mm
MXLE 102C
794
MXLE 103C
963
MXLE 103
963
MXLE 104
1132
MXLE 105
1301
MXLE 106
1470
MXLE 107
1642
MXLE 108
1808
W
Do Not position the equipment so that it is difficult to operate or disconnect from the electrical supply.

3.3 Mechanical Installation

3.3.1 General Requirements

Ensure that each filter condensate drain is suitably piped away and any effluent is disposed of in accordance with local regulations.
It is important to ensure that all piping materials are suitable for the application, clean and debris free. The diameter of the pipes must be sufficient
to allow unrestricted inlet air supply to the equipment and outlet air supply to the application.
When routing the pipes ensure that they are adequately supported to prevent damage and leaks in the system.
All components used within the system must be rated to at least the maximum operating pressure of the equipment. It is recommended that the
system be protected with suitably rated pressure relief valves.
D
W
ins
mm
ins
31.3
1550
61.0
37.9
1550
61.0
37.9
1648
64.9
44.6
1730
68.1
51.2
1730
68.1
57.9
1830
72.0
64.6
1830
72.0
71.2
1830
72.0
D
D
W
13