3 Installation and Commissioning
Only competent personnel trained, qualified, and approved by Parker domnick hunter should perform installation,
commissioning, service and repair procedures.
3.1 Recommended System Layout
The dryer should be installed, downstream of a 'wet' air receiver, with the pre-filtration supplied and optional condensate management equipment
to meet both the specification and local environmental requirements. This includes the following components:
Water separators (Optional) - Water separators are used to protect coalescing filters against bulk liquid contamination, where excessive cooling
takes place in air receivers and distribution piping. Using mechanical separation techniques, Parker domnick hunter water separators will remove
in excess of 92% bulk liquid contamination at all flow conditions.
General purpose and high efficiency coalescing filters (Supplied) - Coalescing filters are probably the single most important items of
purification equipment in a compressed air system. They are designed to not only remove aerosols (droplets) of oil and water using mechanical
filtration techniques, but also to remove solid particulate to very low levels (as small as 0.01micron in size). Installed in pairs, the first filter is a
'general purpose filter' which protects the second 'high efficiency filter' from bulk contamination. The dual filter installation from Parker domnick
hunter ensures a continuous supply of high quality compressed air with the additional benefits of low operational costs and minimal maintenance.
Dust removal filters (Supplied) - Dust removal filters are used for the removal of dry particulates. They provide identical particulate removal
performance to the equivalent coalescing filter and use the same mechanical filtration techniques to provide up to 99.9999% particle removal
efficiency.
Note. Failure to install and maintain the pre and after filtration, supplied with the dryer and configured as illustrated below, will
invalidate the dryers warranty.
Ref
Description
1
MXLE Dryer
2
Vacuum Pump
3
Water Separator
4
General Purpose Filter
12
<2m (78.7 ins)
Ref
Description
5
High Efficiency Filter
6
Dust Filter
7
Isolation Valve
8
Electronic Condensate Drain