The purge plates are fitted to the purge assembly on the rear of the dryer.
1
Unscrew the eight M10 x 35mm hex bolts and washers and remove the assembly from the dryer.
2
Unscrew the M5 socket head cap screws and washers that hold the existing purge plates in place.
3
Select the appropriate purge plates for the required operating pressure and orientate them so that the holes for the required pressure setting
on each plate line up with the holes in the purge assembly.
4
Fit the plates using the 4x M5 socket head cap screws and washers. Ensure that all o-ring seals are located correctly in their grooves, apply
a small amount of grease to the seals to hold them in place.
5
Mount the purge assembly on to the dryer and secure it in place with the M10 bolts (Torque setting: 34Nm / 25lb. ft). Ensure that all o-ring
seals are located correctly in their grooves, apply a small amount of grease to the seals to hold them in place.
Note: Purge plates must be fitted in matched pairs.
3.3.5 Filter Installation
Multiple filters can be installed using the fixing clamps provided. Install the filters as illustrated in a vertical position ensuring that each fixing clamp
is properly secured.
Note: Before positioning the o-ring onto the filter ports, lubricate with a suitable acid free petroleum jelly.