How to proceed:
 S
1. Remove the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated
in the display of the control system.
2. Switch off the filter pump.
3. Switch off the mains voltage (ensure that the control system is isolated).
4. Measure the distance between the top edge of the container and the level of the water and
determine the necessary position of the holder according to the table.
5. If the determined position differs from the current position, correct it as required.
– Undo and remove both screws of the holder. Push the holder into the correct position and
fasten with both screws.
6. Fit the container cover.
7. Switch on the control system and filter pumps and check the function of the status detection.
The status detection is correctly set if the float sinks with the filter pump switched on and the
system message Er88 is only triggered 10 minutes after the filter pump is switched off.
Water level in the filter container/pond
 S
(measured from the top edge of the container with the filter pump
max.
169 mm
162 mm
155 mm
148 mm
141 mm
134 mm
127 mm
120 mm
113 mm
1)
Factory setting
switched off)
min.
189 mm
182 mm
175 mm
168 mm
161 mm
154 mm
147 mm
140 mm
133 mm