Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 159
6.8

System messages

The 4-digit system message is indicated in the display by two groups of two digits in succession.
System message
Container cover raised
Er11
Water temperature >
Er22
12 °C AND the last auto-
matic cleaning process
was carried out more than
24 hours ago.
20 cleaning cycles in suc-
Er33
cession
Functions that are still
Possible cause
available
Container cover raised
• Manual cleaning (only
nozzles, filter drum not
Container cover incorrectly fitted
rotating)
Signal box not connected
• Manual cleaning
Screen elements leaking
• Automatic mode
Drum seal leaking
• Time-dependent
cleaning
Level detection device stuck or
• Extended cleaning time
defective
"Extra Cleaning"
Level detection device set incorrect-
ly
Level detection device stuck or
• Manual cleaning
defective
• Time-dependent
cleaning
Screen elements heavily soiled
• Extended cleaning time
"Extra Cleaning"
Rinsing pump not operating
Rinsing nozzles clogged
Filter drum not rotating
Water in the pond is severely con-
taminated.
Remedy
Refit the container cover
Turn the container cover around so that the magnets in
the container cover are located over the signal box
Connect the signal box to the control system
Check screen elements, replace if necessary
Check the drum seal
Clean the level detection device to ensure that the
mechanism operates freely, replace if necessary.
Adjust the level detection device
(→ Commissioning/start-up)
Clean the level detection device to ensure that the
mechanism operates freely, replace if necessary.
Clean/descale the screen elements (→ Removing the
screen element)
• Clean the bottom of the container, clean the rinsing
pump (→ Cleaning the rinsing pump)
• Check the pump connection
Clean the rinsing nozzles
• Check the motor connection
• Check the rotating movement of the filter drum. To do
so, check the markings (1 - 8) on the filter drum to
detect a rotating movement.
• For the duration of the severe contamination, reduce
the flow rate until the error message is no longer dis-
played.
• For the duration of the severe contamination, use
screen elements with a larger screen mesh size.
- EN -
Resetting the system
message
Automatic when the con-
tainer cover is replaced
• Press
key for 5 s
• Automatic as soon as
the level detection de-
vice is triggered
Press
key for 5 s
75