System message
Functions that are still
available
System message
Functions that are still
available
More than 960 cleaning
Er55
• Manual cleaning
cycles in 48 hours
• Automatic mode
• Time-dependent
cleaning
• Extended cleaning time
"Extra Cleaning"
Switch element for rinsing
None
Er66
pump in the control sys-
tem overheated
The filter pump is not
Er88
• Manual cleaning
supplying any water or
• Automatic mode
insufficient water.
• Time-dependent
cleaning
• Extended cleaning time
"Extra Cleaning"
Possible cause
Remedy
The drum load is distributed une-
• Align the container horizontally
venly
Pump fed system only:
Water level too low
Ensure that the water level in the drum filter is
280 ... 400 mm below the edge of the container.
Gravity fed systems only:
Excessive difference in water level
• Determine the cause of the difference and eliminate it
inlet side/drum side
(e.g. level detection device set too low, screens
clogged, rinsing function inactive)
• Switch off the pumps and wait until the water level is
equal on both sides. Subsequently, switch on the
pumps again and check the difference.
Possible cause
Remedy
Temporary heavy soiling
Wait until the soiling decreases
• Start-up phase of the filter system
• This operating status is atypical. Avoid long-term
(e.g. during the first start-up)
operation in this state.
• Fish are spawning
Pond heavily soiled
• Clean the pond
• Reduce the amount of soiling
Screen elements heavily soiled
Clean/descale the screen elements (→ Removing the
screen element)
Insufficient cleaning effect due to
Clean the nozzles
soiled nozzles
Water level in the system too high:
• Clean outlet pipes
• Outlet pipes soiled
• Enlarge outlet opening
• Outlet opening too small
• Reduce flow rate
• Max. flow rate exceeded
Control system is exposed to ex-
Protect the control system from heat
cessive heat (sun, ambient temper-
ature)
Pump status detection incorrectly
Set the pump status detection. (→ E7: Pump status
set
detection)
The filter pump is switched off.
Switch on the filter pump.
The impeller unit of the filter pump
Clean the filter pump.
is blocked.
- EN -
Resetting the system
message
Resetting the system
message
− Press
key for 5 s
− Automatic if the num-
ber of cleaning proce-
dures drops below 960.
Automatic when cooled
down
Automatic after elimination
of the cause
77