CAUTION! – When assigning addresses to the photocells, the configura-
tion shown in PHOTO 3 below is not permitted.
PHOTO 3
NON-PERMITTED CONFIGURATION
At the end of the installation procedure or following the removal of photocells or
other devices, the self-learning procedure for these devices described in para-
graph 3.4 must be performed.
3.4 - Learning of the connected devices
After the initial power-up, the control unit must be able to recognise the devices
connected to the "Bluebus" and "Stop" inputs. CAUTION! – The learning
procedure must be performed even if no device is connected to the con-
trol unit.
The control unit is able to recognise the various connected devices individually
through the learning procedure and detect possible faults with a high degree of
precision. For this reason it is necessary to perform learning every time a new
device is connected or an existing device is removed.
To indicate when the learning procedure is required, LEDs L1 and L2 on the
control unit emit a number of slow flashes:
01. Press and hold down " " and "Set" keys at the same time.
02. Release the keys when LEDs L1 and L2 start flashing quickly (after approx.
3 seconds).
03. Wait a few seconds for the control unit to complete the device learning
phase. At the end of this phase, the "Stop" LED must be lit and LEDs "L1"
and "L2" must be turned off (LEDs L3 and L4 may start flashing).
3.5 - Learning of type of gearmotor connected to the control
unit and the positions of the mechanical stops
After learning the devices (paragraph 3.4), the control unit must learn the con-
nected motor type (see Table 2) and the positions of the mechanical stops
(max. Opening and max. Closing positions). In this phase, the travel of each leaf
is measured.
Learning of the mechanical stops can be performed in two ways: automatic or
manual.
Using manual learning it is possible to:
• program the automation with all 8 positions and with the sequence described
in Table 3.
• customise the automation after performing automatic learning to modify the
position A (fig. 6) of the 2 motors M1 and M2 or to alter the offsets of the leafs
in positions SA and SC (fig. 6).
• check whether faults occur during a manoeuvre for each individual leaf (use
hold-to-run OPEN and CLOSE keys).
Led
Gearmotor type
L1
MB4024 - MB5024 - HY7024
L2
ME3024
L3
TO4024
L4
TO5024
L5
TO7024
TABLE 3 (fig. 6)
Position
LED Description
Position 0
L1
Maximum closing position: when leaf 1 reaches closing
(motor 1)
mechanical stop
Position 0
L2
Maximum closing position: when leaf 2 reaches closing
(motor 2)
mechanical stop
Position SA
L3
Opening offset: when leaf 2 passes this position the ope-
(motor 2)
ning of leaf 1 begins
Position A
L4
Desired opening position: position at which the leaf con-
(motor 1)
nected to motor 1 must stop at the end of an opening
manoeuvre. This position does not need to coincide with
the opening mechanical stop but can be chosen as desi-
red between the positions 0 and 1
Position A
L5
Desired opening position: position at which the leaf con-
(motor 2)
nected to motor 2 must stop at the end of an opening
manoeuvre. This position does not need to coincide with
the opening mechanical stop but can be chosen as desi-
red between the positions 0 and 1
Position SC
L6
Closing offset: when leaf 1 reaches this position, leaf 2
(motor 1)
begins to close
Position 1
L7
Maximum opening position: when leaf 1 reaches the ope-
(motor 1)
ning mechanical stop
Position 1
L8
Maximum opening position: when leaf 2 reaches the ope-
(motor 2)
ning mechanical stop
2 – English
TABLE 2
Learning procedure in automatic mode:
01. Press and hold down "Set" and " " keys at the same time.
02. Release the keys when LED L1 begins to flash (installation memorisation
not performed) or when any of the LEDs L1 ... L8 light up (installation
memorisation already performed).
03. Press " " or " " keys within 10 seconds to go to the LED corresponding
to the type of gearmotor connected to the control unit (see Table 2).
04. Press and hold down the "Set" key for at least 3 seconds to memorize the
se lected gearmotor. After 3 sec. LED L1 starts flashing, then release the
key.
05. Press and hold down "Set" and " " keys at the same time.
06. Release the keys when LEDs L3 and L4 begin to flash quickly (after
approx. 3 seconds).
07. Check that the automation performs the following sequences of manoeu-
vres:
a - Slow closure of gearmotor M1 as far as mechanical stop
b - Slow closure of gearmotor M2 as far as mechanical stop
c - Slow opening of gearmotor M2 and gearmotor M1 as far as mechani-
cal stop
d - Complete fast closure of gearmotors M1 and M2
Note – If the first two manoeuvres (a and b) are not "closure" but "open-
ing" manoeuvres, press the "open" or "close" keys to stop the learning
procedure. Now, on the gearmotor that performed the opening manoeu-
vre, invert the polarities of the two wires of the gearmotor (M1: terminals 7
and 9 - M2: terminals 10 and 12) and repeat the procedure from point 01.
08. At the end of the closure manoeuvre of the 2 motors (d), the LEDs L3 and
L4 turn off to indicate that the procedure has been completed correctly.
Learning procedure in manual mode:
Important – To go from one "position" to a subsequent or previous one, press
and immediately release the " " or " " keys.
01. Press and hold down "Set" and " " keys at the same time.
02. Release the keys when LED L1 begins to flash (installation memorisation
not performed) or when any of the LEDs L1 ... L8 light up (installation
memorisation already performed).
03. Press " " or " " keys within 10 seconds to go to the LED corresponding
to the type of gearmotor connected to the control unit (see Table 2).
04. Press and hold down the "Set" key for at least 3 seconds to memorize the
se lected gearmotor. After 3 sec. LED L1 starts flashing, then release the key.
05. • position 0 of M1 (LED L1 flashes)
To bring motor 1 to position 0: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L1 remains on and
on releasing the "Set" key LED L2 begins flashing).
• position 0 of M2 (LED L2 flashes)
To bring motor 2 to position 0: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L2 remains on and
on releasing the "Set" key LED L3 begins flashing).
• position SA of M2 (LED L3 flashes)
To bring motor 2 to position SA: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L3 remains on and
on releasing the "Set" key LED L4 begins flashing).
• position A of M1 (LED L4 flashes)
To bring motor 1 to position A: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L4 remains on and
on releasing the "Set" key LED L5 begins flashing).
• position A of M2 (LED L5 flashes)
To bring motor 2 to position A: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L5 remains on and
on releasing the "Set" key LED L6 begins flashing).
• position SC of M1 (LED L6 flashes)
To bring motor 1 to position SC: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L6 remains on and
on releasing the "Set" key LED L7 begins flashing).
• position 1 of M1 (LED L7 flashes)
To bring motor 1 to position 1: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it (after 2 seconds LED L7 remains on and
on releasing the "Set" key LED L8 begins flashing).
• position 1 of M2 (LED L8 flashes)
To bring motor 2 to position 1: press and hold down the " " or " "
keys. On reaching the position, release the key to stop the manoeuvre.
To memorise the position, press and hold down the "Set" key for at least
3 seconds and then release it to exit programming (after 2 seconds LED
L8 remains on until the "Set" key is released).