For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood
shims the width of the trim and attach them to the cabinet
bottom recess on both sides.
Installation to wall
(Horizontal duct– 3 1/4"x 10" Rectangular)
• Use the diagram or the hood as a template and mark the
locations on the wall for ductwork, electrical wiring and
keyhole screw slots.
3"
10-5/8"
(30" Model
36" Model)
Install framing for hood support
If drywall is present, mark the screw hole locations.
Remove the template.
Cut away enough drywall to expose 2 vertical studs at
the holes location indicated by the template.
Install two horizontal supports at least 4" X 2" between
two wall studs at the bottom and upper mounting holes
installation location.
The horizontal support must be flush with the room side
of the studs.
Use cleats behind both sides of the support to secure to
wall studs.
Reinstall drywall and refinish.
IMPORTANT- Framing must be capable of supporting
100 lbs.
21/32"
10-5/8"
(30" Model
36" Model)
Cut holes at marked locations for duct and electrical wiring.
For the vertical duct, cut out 3/4" extra toward the front of
the cabinet so you can move the duct freely when installing
the hood.
It may also ease installation by cutting the hole 10 1/2"
instead of 10".
Drive a mounting screw (from the hardware packet) partway
into each center of the narrow neck of the keyhole slots
marked on the cabinet bottom.
Fix the wiring conduit to the hood.
Slide the hood back against the wall. Tighten the mounting
screws. Be sure the screw heads are in the narrow neck of
the keyhole slot.
Connect Ductwork to hood.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction
box.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
Final installation step
Replace the 2 lateral supports.
Replace filters.
Check operation of the hood.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the "Use and Care Information" section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.