INSTRUCTION MANUAL FOR WIRE FEEDER
IMPORTANT:
BEFORE STARTING THE EQUIPMENT,
READ THE CONTENTS OF THIS MANUAL, WHICH MUST
BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR
THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WELD-
ING OPERATIONS.
FOR THE DIMENSIONS AND WEIGHT OF THIS WELDING
MACHINE, SEE THE SPECIFIC CATALOGUE.
1 SAFETY PRECAUTIONS
WELDING AND ARC CUTTING CAN BE HARMFUL TO
YOURSELF AND OTHERS. The user must therefore be edu-
cated against the hazards, summarized below, deriving from
welding operations. For more detailed information, order the
manual code 3.300.758
ELECTRIC SHOCK - May be fatal.
· Install and earth the welding machine according to
the applicable regulations.
· Do not touch live electrical parts or electrodes with
bare skin, gloves or wet clothing.
· Isolate yourselves from both the earth and the workpiece.
· Make sure your working position is safe.
FUMES AND GASES - May be hazardous to your health.
· Keep your head away from fumes.
· Work in the presence of adequate ventilation, and
use ventilators around the arc to prevent gases from
forming in the work area.
ARC RAYS - May injure the eyes and burn the skin.
· Protect your eyes with welding masks fitted with fil-
tered lenses, and protect your body with appropriate
safety garments.
· Protect others by installing adequate shields or curtains.
RISK OF FIRE AND BURNS
· Sparks (sprays) may cause fires and burn the skin;
you should therefore make sure there are no flam-
mable materials in the area, and wear appropriate
protective garments.
NOISE
This machine does not directly produce noise
exceeding 80dB. The plasma cutting/welding proce-
dure may produce noise levels beyond said limit;
users must therefore implement all precautions required by
law.
PACEMAKERS
· The magnetic fields created by high currents may affect the
operation of pacemakers. Wearers of vital electronic equip-
ment (pacemakers) shall consult their physician before
beginning any arc welding, cutting, gouging or spot welding
operations.
EXPLOSIONS
· Do not weld in the vicinity of containers under pres-
sure, or in the presence of explosive dust, gases or
fumes.
· All cylinders and pressure regulators used in welding oper-
ations should be handled with care.
6
ELECTROMAGNETIC COMPATIBILITY
This machine is manufactured in compliance with the
instructions contained in the harmonized standard IEC
60974-10, and must be used solely for professional pur-
poses in an industrial environment. There may be poten-
tial difficulties in ensuring electromagnetic compatibility
in non-industrial environments.
DISPOSAL OF ELECTRICAL AND ELECTRONIC
EQUIPMENT
Do not dispose of electrical equipment together
with normal waste!In observance of European
Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with
national law, electrical equipment that has reached the
end of its life must be collected separately and returned
to an environmentally compatible recycling facility. As
the owner of the equipment, you should get information
on approved collection systems from our local represen-
tative. By applying this European Directive you will
improve the environment and human health!
IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL.
2 GENERAL DESCRIPTION
2.1 SPECIFICATIONS
This manual has been prepared for the purpose of edu-
cating personnel assigned to install, operate and service
the welding machine.
The purchaser should address any complaints for los-
ses or damage to the vector. Please indicate the arti-
cle and serial number whenever requesting informa-
tion about the welding machine.
3 INSTALLATION
• Only skilled personnel should install the machine .
• All connections must be carried out according to cur-
rent regulations, and in full observance of safety laws.
3.1 PLACEMENT
Unpack the wire feeder and place it above the welding
machine, using the flexible rotating cylinder provided.
At the first start stage the operator must select the article he
wants to use.
Once the generator has been connected to the carriage by
means of the connector, the machine can be started.
The screen H of the wire feed carriage shows 3 flashing
lines; to select just push one of the 2 push-buttons N or O to
display the welder article you want to use.
4 DESCRIPTION OF CONTROLS
4.1 CONTROLS ON THE FRONTOF THE MACHINE.
A- Green LED.
Signals that the display H shows the current
HOLD
or voltage value measured during welding.
To display one of the two values, simply press one of the
two selection keys N or O.