complete, the LED and display remain lit for 5 seconds.
By using the 2 selector switches R and S from within any
synergic program, pressing one of the 2 keys toggles the
LEDs I, L, M, and display H alternates displaying the cur-
rent, recommended thickness and voltage. This function
is useful when you need to know in advance at what cur-
rent, voltage or thickness you wish to weld.
Pressing the 2 keys simultaneously for at least 5 seconds
causes us to enter the sub-menu, where we find the fol-
lowing functions that may be selected via the key E:
1 - Spot welding time.
When this function is selected the display H shows the
letter (E). Using one of the 2 keys you may adjust the spot
welding or working time, which may range from 0.3 to 5
seconds. Setting the time to 0 disables the function. The
function is active only while welding.
2 - Pause time of the jog function.
When this function is selected the display H shows the
letter (F). Using one of the 2 keys you may adjust the
pause time between welding segments, which may range
from 0.3 to 5 seconds. Setting the time to 0 disables the
function. The function is active only while welding, and if
any spot welding or working time is active.
3 - Burn-back.
When this function is selected the display H shows the
letter (b). Using one of the 2 keys you may adjust the time
for which the wire continues to be output from the weld-
ing torch after the operator has released the button. This
time ranges from 10 to 400 milliseconds.
4 - Soft start (speed).
When this function is selected the display H shows the
letter (A).
Changes the wire speed from the one set; this speed
remains active for the time governed by the Soft Start
function (time).
The speed may be adjusted using the 2 keys N and O
from 10% to a maximum of 150% of the set welding
speed. This function, combined with the soft start func-
tion (time), serves to improve arc striking.
5 - Post gas.
When this function is selected the display H shows the
letter (P).
Using the two keys N and O, it is possible to adjust the
gas flow after welding to between 0 and 10 seconds.
This function is especially useful when welding stainless
steel and aluminum.
6 - Soft Start (time).
When this function is selected the display H shows the
letter (d).
Adjusts the time for which the soft start speed remains
active. This function, combined with the soft start func-
tion (speed), serves to improve arc striking.
Using the 2 keys N and O, the soft start time may be
adjusted from 0 to 1 second.
8
P- Setting knob.
When using any synergic program, the
SYNERGIC
knob indicator must be set to the label
5
6
7
4
SYNERGIC.
gram is selected, the display H shows
3
8
the set current.
2
9
This current corresponds to a given
1
10
speed. If you wish to correct this
speed, simply turn the knob clockwise
to increase or counter-clockwise to
decrease.
Changes in wire speed are always indicated on the dis-
play H by a current.
When the program 00 (manual) is in use, adjusts the wire
speed from 0 to 20 meters per minute.
The display H shows the meters per minute.
T - Quick-fitting socket.
This fitting must be connected to the red water
hose leaving the welding torch.
U - Quick-fitting socket.
This fitting must be connected to the blue water
hose leaving the welding torch.
4.2 CONTROLS ON THE WIRE FEEDER REAR PANEL
Q
R
S
Q - Gas hose fitting for extension gas hoses.
R - 14-pin socket connector for 14-pin plug connector
S - Socket for extension power supply plug.
When a synergic pro-