Alarm Buzzer Setting (ALARM BUZZER)
This item lets you select whether or not to sound the alarm
buzzer when an alarm is activated.
1. Display the ALARM SETUP menu.
2. Select ALARM BUZZER by moving the joystick up or
down.
3. Select ALARM BUZZER ON or OFF by moving the joy-
stick to the right or left.
The initial factory setting is ON.
Note: The alarm buzzer time differs depending on (4) alarm
output setting.
Alarm Preset Position Setting
(ALARM PRESET)
This item lets you preset a camera position to an alarm
input. The camera will move its pan/tilt head to the position
when the alarm operates.
• The menu below appears when the ALARM switch on
the rear of the controller is set to the upper position to
connect with a Time Lapse VTR.
ALARM DISPLAY ON
SITE ALARM
TERM.ALARM
ALARM OUTPUT
ALARM BUZZER
ALARM PRESET
1. Display the ALARM SETUP menu.
2. Select ALARM PRESET by moving the joystick up or
down.
3. Move the joystick to the right or left to select the
desired preset numbers of the picture on the moni-
tor in the range from 1-64 or [–] if no preset num-
bers are assigned.
The initial factory setting is – (No assignment).
1-64: Preset numbers
–: No assignment
Note: ALARM PRESET is only available when a
combination camera is connected.
20
ALARM SETUP
ON
ON
10S
ON
Alarm Terminal (ALARM TERMINAL)
The menu below appears when the ALARM switch on the
rear of the controller is set to the lower position to receive
the four sensor inputs.
ALARM SETUP
ALARM DISPLAY ON
SITE ALARM
TERM.ALARM
ALARM OUTPUT
ALARM BUZZER
ALARM TERMINAL
1. Display the ALARM SETUP menu.
2. Select ALARM TERMINAL by moving the joystick up or
down.
3. Press the PRESET/SET/PROGRAM PRESET button.
The ALARM TERMINAL menu opens.
ALARM TERMINAL
ALARM
1
2
3
4
4. Select the alarm terminal number by moving the joystick
up or down.
5. Move the joystick to the right or left to select the desired
preset numbers.
The initial factory setting is – (No assignment).
1-64: Preset numbers
–: No assignment
6. Press the HOME/ESC button to return to the previous
menu.
Notes:
• ALARM TERMINAL is only available when a combina-
tion camera is connected.
• If the camera has the Preset Alarm ON/OFF mode, then
set it to OFF.
ON
ON
10S
ON
PRESET
-
-
-
-