Cabinet Requirements; Electrical Connection - Franke FS 913 M Manual De Instalación

Horno multifunción
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
EN
InstallatIon
Installation must be carried out in compliance with current standards and
regulations.
Installation must only be carried out by specialised and licensed personnel.

Cabinet requirements

For fitted units, the components (plastic materials and veneered wood) must be
assembled with heat-resistant adhesives (min. 100°C): Unsuitable materials and
adhesives can result in warping and detachment.
The cabinet for the oven must allow sufficient room for the electrical connections of
the oven.
The cabinet for the oven must be sturdy enough to withstand the weight of the oven.
The oven must be securely installed in the recess. The oven can be installed in a
column housing unit or below the countertop of a modular unit, provided sufficient
ventilation is guaranteed.

Electrical connection

FRANKE ovens can have two types of connection. Each FRANKE oven is supplied
with one of these types:
– Power SCHUKO plug (Fig. 3a)
– Three free terminals (a three-pole power cable with free terminals) (Fig. 3b).
In this case the connection polarities
of the free terminals are as follows:
Brown = Line
Blue = Neutral
Yellow / Green = Earth
Make sure the characteristics of the household electrical system (voltage,
X
X
maximum power and current) are compatible with those of the oven.
If the oven is to be permanently connected to the power supply:
Install a device that enables disconnection from the power supply, with a contact
X
X
opening distance (3 mm) that ensures complete disconnection in category III
overvoltage conditions.
FS 913 M / FS 913 P / FS 982 M
yellow/green
– 4 –
blue
brown

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fs 913 pFs 982 mCrystal cr 913 mCrystal cr 982 m

Tabla de contenido