Installation requirements

Product dimensions are provided in the Figure 2.
Furniture surfaces for mounting and mounting
materials to be used must have a minimum
temperature resistance of 100 °C.
Mounting cabin must be secured and its floor
must be plane for product not to tilt over.
Cabin floor must have a minimum strength that
would handle a load of 60 kg.

Placing and securing the oven

X
Z
Place the oven into the cabin with two or
more people.
X
Z
Ensure that oven's frame and front edge of
the furniture match uniformly.
X
Z
Supply cord mustn't be under the oven,
squeeze in between oven and furniture
or bend.
X
Z
Fix the oven to the furniture by using the
screws provided with the product. Screws
must be mounted as shown in Figure 4 by
passing them through plastics attached to
frame of the product.
X
Z
Screws mustn't be overtightened.
Otherwise, screw sockets might be
worn. Check that oven doesn't move
after mounting. If oven isn't mounted
in accordance with instructions, there
is a risk of tilt over during operation.

Electrical connection

Mounting place of the product must have
appropriate electrical installation.
Network voltage must be compatible with the
values provided on type label of product.
Product connection must be made in
accordance with local and national electrical
requirements.
Z
Z
Before starting the mounting disconnect
network power.
Z
Z
Do not connect the product to network until
its mounting is completed.
GN 86 M H XS / GN 86 M H BK / GN 86 M H WH
WARNING:This oven must be installed
and connected to its place correctly according
to manufacturer instructions and by an
authorized service.
WARNING: Appliance must be
installed in an oven enclosure providing high
ventilation.
WARNING: Electrical connections of
the appliance must be made only via sockets
having earth system furnished in compliance
with rules.
Z
Z
Contact an authorized electrician if there
is no socket complying with the earthed
system at where appliance will be placed.
Manufacturing company is by no means
responsible for damage resulting from
connection of non-earthed sockets to
appliance.
Z
Z
Plug of your oven must be earthed; ensure
that socket for the plug is earthed.
Z
Z
Plug must be located in a place that can be
accessed after installation.
CAUTION: Your oven has been manufactured
as 220-240 V 50/60 Hz. AC power supply
compliant and requires a 16 Amp fuse.
If your power network is different that these
indicated values, refer to an electrician or your
authorized service.
CAUTION: When you need to replace the
electrical fuse, please ensure that electrical
connection is made as follows:
Brown = Live
Blue = Neutral
Yellow/Green = Earth
Oven disconnecting switches must be in an
accessible place for final user while oven is in
its place.