Solenoid Valve For Gas Burners (Low Pressure) - baltur BTG 3,6 Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The symbol EG 12*S...-E6G* normally indicates rapid closing,rapid or slow
opening valves whith rapid and adjusatble release for the initial flow rate.
Version EG 12*S... (see Fig. 1) and EG 12*L...E6G* are powered by alternating
current while a rectifier circuit in the solenoid valve supplies the coil with direct
current power.
All EG 12*... solenoid have two fittings for the installation of UNI-ISO 228/1 G 1/
4" pressure points. Each valve is fitted with an upstream filter to prevent the
infiltration of solid particles with f>1mm.
Solenoid valve EG 12*SR... (see Fig. 2) differs from the EG 12*S...models by the
presence of a downstream flow regolator device.
Solenoid EG 12*L...-E6G* (see Fig. 3) permits gradual burner ignition by delayed
valve opening throw the action of a hydraulic damper installed in direct contact
with the moving part.
Solenoid valve EG 12*L...-E6G both regulates the opening time and rapid release
for the initial flow rate. The maximum flow rate can be regulated by adjusting the
damper block.
Maximum guaranteed operating pressure: 250 mbar;500mbar (E6G)
Class: A
Operating temperature: -10/+60°C
Power supply: 230 V 50/60 Hz
Protection class: IP54
ADIUSTMENT INSTRUCTIONS FOR SOLENOID VALVE
EG 12*...and E6G*
Flow rate adjustment:
To vary the gas flow rate to the burner, adjust block 3 of the time delay device
shown in Fig. 4.
Stacken the cover lock screw (only salken the screw without paint seal) and
rotate the entire unit.
Turn clockwise to reduces the flow rate and counter-clockwise to increase it.
Maximum adjustment is determined by the regulator screw stop and a thrust
ring, wich are both fitted inside the sheath.
Solenoid valve opening time adjustement:
Turn adjustment screw 1 shown in Fig. 4.clockwise to shut off the oil hole for
more rapid opening of the valve.
N.B.:
Adjustement screw 1 is supplied correctly calibrated by the
manufacturer and must not therefore be re-adjustef.
Adjustement of initial flow rate rapid release:
Rotate regulator 2 shown in Fig. 4. Using a 6mm hexagonal wrench, turn the
regulator clockwise to reduce the release time and counter-clockwise to
increase it.
INSTRUCTIONS FOR THE ADJUSTEMENT OF
SOLENOID VALVES EG 12*AR TO EG12*SR
Flow rate adjustement:
To vary the gas flow rate, adjust regulator A using an 8 mm
hexagonal wrench or 4 mm hexagonal socked wrench
Turn the regulator clockwise to reduce the flow rate and counter-clockwise
to increase it.
BRAHMA SOLENOID VALVE MOD. EG 12*...and
E6G* FOR GAS BURNERS (LOW PRESSURE)
Spring: stainless steel
Coil coating: PA6
Operating frequency: unlimited
Class A electromagnetic safety valves to
DIN 3394 and EN 161.
28
N° 0002910220
REV. 30/09/94

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btg 6Btg 11Btg 3

Tabla de contenido