Specifications; Powered Air Purifier; Battery Packs; Battery Charger - 3M GVP Serie Manual De Instrucciones

Ocultar thumbs Ver también para GVP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS

Powered Air Purifier

Noise Level (excluding external noise)
Operating Temperature Range
Decontamination of PAPR Unit (Motor Blower)
Voltage
Estimated Motor Life

Battery Packs

BP-15 (NOT INTRINSICALLY SAFE) Rechargeable NiMH (Nickel Metal Hydride)
Service Time
Charging Time
Maximum Time on Continuous Charge
Battery Recharge Indicator
Storage Time
Maximum Operating Temperature Range
Battery Charging Temperature Range
Voltage
Battery Life
GVP-111 Rechargeable NiCd, Intrinsically Safe
Service Time
Charging Time
Maximum Time on Continuous Charge
Battery Recharge Indicator
Storage Time
Maximum Operating Temperature Range
Battery Charging Temperature Range
Voltage
Circuit Breaker (resetting) will open if the battery is exposed to high temperatures. Will reset when the inside battery temperature is less than
122ºF (50ºC).
Battery Life

Battery Charger

BC-210 charger for BP-15 NiMH Battery
Input
Output
GVP-112 charger for GVP-111 NiCd Battery
Input
Output
Less than 80 dBA
10ºF to 120ºF (-12ºC to 49ºC)
With the inlet and outlet plugs in place the unit may be rinsed with water/mild detergent or
placed into equipment dishwasher. Limit water temperature to a maximum 120°F (49°C).
4.8 Volts DC
2000 hours (Dependent on use conditions)
Approximately 8 hours of continuous use
2 hours for 90% charge and 4 hours for complete charge on a fully discharged battery
Recommend storing battery on BC-210 charger when not in use.
Indicates recharging is required. Battery will shut down in 10 to 15 minutes after indicator
illuminates.
Battery will lose approx. 20% capacity per month
10°F to 120°F (-12°C to 49°C)
50°F to 90°F (10°C to 32°C)
6.25 Volts DC
Approximately 400 discharge cycles. Number of cycles is dependent on temperature conditions
during use and recharging.
Approximately 8 hours of continuous use
20 hours initial charge, 14-16 hours after 8 hours of use
Up to 1 week
Indicates recharging is required or bad cell in the battery. (This indicator does not measure
airflow.)
Battery will lose approx. 20% capacity per month
10ºF to 120ºF (-12ºC to 49ºC)
41ºF to 77ºF (5ºC to 25ºC)
4.8 Volts DC
Approximately 500 to 1000 discharge cycles. Number of cycles is dependent on temperature
conditions during use and recharging.
100-220 Volts AC
12 Volts DC, 4.0 Amps
110-120 Volts AC
6.8 Volts DC, 0.75 Amps
4

Publicidad

Tabla de contenido
loading

Tabla de contenido