8
Adjust Temperature with Water Running
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a
safe water temperature. Water
in excess of 110°F (43°C) may
cause scalding.
9

Trap Cover

Make all connections before installing trap cover.
Hang the trap cover onto
A
the hook, then secure the
trap cover with the screws
provided, starting with the
side screws.
Bradley • 215-1779 Rev. G: ECN 19-08-037A
A
Loosen Cap Screw about 1/4" (4-6
turns) and lift up cover (do not
remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
#10-24
Finishing
Flat Head
Washer
Screw
H
Hook
Washer
#10-24
Screw
2/27/2020
LVLD3
C